Standards
The Jøtul C 550 CB Rockland fireplace insert has been
tested and listed to the following standards:
U.S: ANSI/UL 1482-2011
Canada: ULC-S628-1993
Certified Safety Tests performed by:
ITS, Intertek Testing Services
Middleton, Wisconsin
Manufactured by:
Jøtul North America
55 Hutcherson Drive
Gorham, Maine 04038-2644

Combustion Specifications

Jøtul C 550 Rockland
1
Heat Output Range:
11,700 to 34,900 BTU/hr.
Max. Heat Output:
65,000 BTU/hr.
2
Heating Capacity:
Up to 1,700 sq. ft.
2
Maximum Burn Time:
Up to 9 hours
3
Combustion Efficiency:
4
CO Emissions:
5
Pariculate Emissions:
Fuel: Up to 24" Logs (610 mm)
See the Operation section of this manual for important
information regarding the safe, proper, and most efficient
operation of your stove.
1 Heat Output Range results are determined during
specific emissions tests established by the EPA.
The Maximum Heat Output value is representative of a
more frequent re-fueling cycle than specified in the EPA
High Heat Output test method.
2 Heating Capacity and Maximum Burn Time will vary
depending on design of home, climate, wood type and
operation
3
High Heat Value and Low Heat Value are obtained per CSA
B415.1-10 test method. HHV calculation encompasses all
products of combustion, including water condensation.
LHV calculation includes water in its vapor state. Simply
put, HHV assumes all the water component is in a liquid
state (condensed) at the end of combustion and that
heat recovered from condensation can be put to use.
4
Carbon Monoxide Emissions rate results from Test
Method CSA B415.1-10.
5.
Particulate Emissions rate is obtained using EPA Test
Method 28-5H.
HHV
LHV
71.48%
77.28%
141.62 g/hr
4.5 g/hr
Jøtul C 550 CB Rockland 139656_09 10/18
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2015 U.S.
Environmental Protection Agency's
emission limits for wood heaters
manufactured after May 15, 2015.
This appliance is not approved for sale after
May 15, 2020.
Check Building Codes
When installing, operating and maintaining your
Jøtul C 550 CB fireplace insert, follow the guidelines
presented in these instructions, and make them available
to anyone using or servicing the stove.
In the U.S., the National Fire Protection Association's Code,
NFPA 211, Standards for Chimneys, Fireplaces, Vents and
Solid Fuel Burning Appliances, or similar regulations, may
apply to the installation of a solid fuel burning appliance
in your area.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
THE JOTUL C 550 CB ROCKLAND FIREPLACE INSERT IS NOT
APPROVED FOR USE IN MOBILE HOMES.
NOTE:
CONSULT THE AUTHORITY HAVING
JURISDICTION IN YOUR LOCALE
( SUCH AS MUNICIPAL BUILDING
DEPARTMENT, FIRE DEPARTMENT,
FIRE PREVENTION BUREAU,
ETC. ) BEFORE INSTALLATION TO
DETERMINE THE NEED TO OBTAIN A
PERMIT.