Standards
The Jøtul C 350 Winterport fireplace insert has been
tested and listed to the following standards:
U.S: ANSI/UL 1482 (2011)
Canada: ULC S-628 (1993)
Certified Safety Tests performed by:
ITS, Intertek Testing Services
Middleton, Wisconsin
Manufactured by:
Jøtul North America
55 Hutcherson Drive
Gorham, Maine 04038-2644
Combustion Specifications
Jøtul C 350 Winterport
1
Heat Output Range:
Max. Heat Output:
2
Heating Capacity:
2
Maximum Burn Time:
3
Combustion Efficiency:
4
CO Emissions:
5
Pariculate Emissions:
Fuel: 20" Logs (508 mm)
See the Operation section of this manual for important
information regarding the safe, proper, and most efficient
operation of your stove.
1
Heat Output Range results are determined during
specific emissions tests established by the EPA.
The Maximum Heat Output value is representative of a
more frequent re-fueling cycle than specified in the EPA
High Heat Output test method.
2 Heating Capacity and Maximum Burn Time will vary
depending on design of home, climate, wood type and
operation
3
High Heat Value and Low Heat Value are obtained per
CSA B415.1-10 test method. HHV calculation encompasses
all products of combustion, including H2O condensation.
LHV calculation includes H2O in its vapor state. Simply
put, HHV assumes all the water component is in a liquid
state (condensed) at the end of combustion and that
heat recovered from condensation can be put to use.
4
Carbon Monoxide Emissions rate results from Test
Method CSA B415.1-10.
5.
Particulate Emissions rate is obtained using EPA Test
Method 28-5H.
11,420 to 34,200 BTU/hr.
40,000 BTU/hr.
Up to 1,300 sq. ft.
Up to 7 hours
HHV
74.20%
93.17 g/hr
4.0 g/hr
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2015 U.S.
Environmental Protection Agency's
emission limits for wood heaters
manufactured after May 15, 2015.
Check Building Codes
When installing, operating and maintaining your
Jøtul C 350 Winterport fireplace insert, follow the
guidelines presented in these instructions, and make them
available to anyone using or servicing the stove.
In the U.S., the National Fire Protection Association's Code,
NFPA 211, Standards for Chimneys, Fireplaces, Vents and
LHV
Solid Fuel Burning Appliances, or similar regulations, may
80.20%
apply to the installation of a solid fuel burning appliance
in your area.
In Canada, the guideline is established by the CSA
Standard, CAN/CSA-B365-M93, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or authority
having jurisdiction to determine what regulations apply
in your area.
THE JOTUL C 350 FIREPLACE INSERT IS NOT APPROVED FOR
USE IN MOBILE HOMES.
NOTICE:
YOU SHOULD CONSULT THE AUTHORITY
HAVING JURISDICTION IN YOUR LOCALE
(SUCH AS MUNICIPAL BUILDING
DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, ETC.) BEFORE
INSTALLATION TO DETERMINE THE NEED
TO OBTAIN A PERMIT.
Jøtul C 350 Winterport 138376_Rev_R 7/18
3