Please read the entire Information and Welcome Guides before using your device.
Indications for use
The S9 AutoSet CS-A is indicated to stabilise the ventilation of adult patients exhibiting central
sleep apnoea (CSA), mixed sleep apnoea and periodic breathing, with or without obstructive
sleep apnoea. It is intended for home and hospital use.
Contraindications
ASV therapy is contraindicated in patients with chronic, symptomatic heart failure with reduced
left ventricular ejection fraction (LVEF ≤ 45%).
Positive airway pressure therapy may be contraindicated in some patients with the following pre-
existing conditions:
severe bullous lung disease
pneumothorax or pneumomediastinum
pathologically low blood pressure, particularly if associated with intravascular volume depletion
dehydration
cerebrospinal fluid leak, recent cranial surgery, or trauma.
Adverse effects
Patients should report unusual chest pain, severe headache, or increased breathlessness to their
prescribing physician. An acute upper respiratory tract infection may require temporary
discontinuation of treatment.
The following side effects may arise during the course of therapy with the device:
drying of the nose, mouth, or throat
nosebleed
bloating
ear or sinus discomfort
English
1

Advertisement

Table of Contents
loading

Summary of Contents for ResMed S9 AutoSet CS-A

  • Page 1 Please read the entire Information and Welcome Guides before using your device. Indications for use The S9 AutoSet CS-A is indicated to stabilise the ventilation of adult patients exhibiting central sleep apnoea (CSA), mixed sleep apnoea and periodic breathing, with or without obstructive sleep apnoea.
  • Page 2: Troubleshooting

    • skin rashes. Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device enclosure. Problem/Possible cause Solution No display Power is not connected.
  • Page 3 SmartStart/Stop is enabled but the device does not stop automatically when you remove your mask Incompatible mask system Only use equipment recommended by ResMed. being used. Incorrect mask setting being Check the selected mask type in the Setup menu. Change it if used.
  • Page 4 Turn the humidity level setting down and empty the water from high, resulting in accumulation the air tubing. of water in the air tubing. Check ResMed 30/90W Power Supply Unit and fully insert the connector Displays message: The DC plug is partially inserted Fully insert the DC plug.
  • Page 5 Problem/Possible cause Solution You may have removed the Reinsert the SD card and wait for the Home screen or the "Settings updated successfully, press any key" SD card before settings were message to copied to the device. appear on the LCD. Note: This message only appears once.
  • Page 6 Problem/Possible cause Solution No tube, please check your tube is connected Displays message: Flow is high because air tubing Connect the air tubing firmly at both ends. is not connected properly. Note: The tube disconnection check may not operate when an antibacterial filter is used.
  • Page 7 If the message appears repeatedly but the oximeter adapter is faulty. attached properly, the oximeter adapter might be faulty. Contact your service provider. Check ResMed 30/90W Power Supply Unit Displays message: The power supply unit is being Make sure that the power supply unit is free from bedding, clothes covered by bedding.
  • Page 8 Information regarding the electromagnetic emissions and immunity of this ResMed device can be found on www.resmed.com, on the Products page under Service and Support. Click on the PDF file for your language. Class II (double insulation), Type BF, Ingress protection IP21...
  • Page 9 Physical Nominal dimensions (L x W x H): 153 mm x 172 mm x 86 mm Weight: 1.04 kg Housing construction: Flame retardant engineering thermoplastic Air outlet: 22 mm conical air outlet (complies with ISO 5356-1:2004) Air filter Hypoallergenic air filter: Acrylic and polypropylene fibers in a polypropylene carrier Standard air filter: Polyester non-woven fiber Sound...
  • Page 10 Air tubing technical specifications Air tubing Material Length Inner diameter ClimateLine heated air tubing Flexible plastic and electrical 15 mm components Flexible plastic and electrical 1.9 m 19 mm ClimateLine heated air components tubing SlimLine air tubing Flexible plastic 1.8 m 15 mm Standard air tubing Flexible plastic...
  • Page 11: Humidifier Performance

    Humidifier performance The following settings have been tested at 22°C ambient temperature: Mask pressure RH output % Nominal system output AH , BTPS cm H Setting 3 Setting 6 Setting 3 Setting 6 11.5 13.5 a. AH - Absolute Humidity in mg/L. b.
  • Page 12: Displayed Values

    Displayed values Value Range Display resolution Pressure sensor at air outlet Mask pressure 4–20 cm H O (CPAP); 4–30 cm 0.1 cm H O (ASV, ASVAuto modes) Flow derived values Leak 0–200 L/min 1 L/min Tidal volume 0–4000 mL 1 mL Respiratory rate 0–50 BPM 1 BPM...
  • Page 13: Pressure Accuracy

    Pressure accuracy Maximum static pressure variation at 10 cm H O according to EN ISO 17510-1:2009 Standard air tubing SlimLine air tubing Without H5i 9.89 cm H O to 9.97 cm H 9.76 cm H O to 9.87 cm H With H5i 9.82 cm H O to 9.98 cm H...
  • Page 14: Limited Warranty

    ResMed. ResMed recommends that the AutoSet CS-A device be inspected and serviced by an authorised ResMed Service Centre if there is any sign of wear or concern with device function. Otherwise, service and inspection of the devices generally should not be required during the five year design life of the device.
  • Page 15 Portable diagnostic/screening devices This warranty is only available to the initial consumer. It is not transferable. If the product fails under conditions of normal use, ResMed will repair or replace, at its option, the defective product or any of its components.
  • Page 16 If you notice any unexplained changes in the performance of the device, if it is making unusual or harsh sounds, if the device or the power supply are dropped or mishandled, if water is spilled into the enclosure, or if the enclosure is broken, discontinue use and contact your ResMed Service Center.
  • Page 17 • Only use the ResMed 90W or 30W power supply unit. Use the 90W power supply unit to power the system comprising the device, H5i, air tubing, DC/DC converter and battery pack. The 30W power supply unit is designed to power the device only and recommended for travelling.
  • Page 18 Manufacturer: ResMed Pty Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia. Distributed by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA. ResMed (UK) Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire OX14 4RW UK. See www.resmed.com for other ResMed locations worldwide.

Table of Contents