ResMed S9 Series Welcome Manual
ResMed S9 Series Welcome Manual

ResMed S9 Series Welcome Manual

Positive airway pressure device
Hide thumbs Also See for S9 Series:

Advertisement

S9
Auto 25
POSITIVE AIRWAY PRESSURE DEVICE
Welcome Guide
English

Advertisement

Table of Contents
loading

Summary of Contents for ResMed S9 Series

  • Page 1 Auto 25 ™ POSITIVE AIRWAY PRESSURE DEVICE Welcome Guide English...
  • Page 3 Welcome Thank you for choosing the Auto 25. Before operating this device, please read the entire Welcome and Information Guides. SD card slot Module/Adapter port DC power inlet Air filter Air outlet Auto 25 at a glance The Auto 25 system comprises the following elements: •...
  • Page 4 5. Connect the assembled mask system to the free end of the air tubing. Notes: • For more information on assembling your mask see your mask user guide. • Recommended masks are available on www.resmed.com on the Products page under Service & Support.
  • Page 5 Auto 25 basics LCD screen Displays the menus, treatment screens and reminders. Start/Stop button Starts or stops treatment. Key: Home Humidity level Ramp Setup menu* Allows you to Heated tube make changes to settings or Climate exit from the Info menu* Control menu.
  • Page 6: Using Mask-Fit

    Adjusting ramp time Designed to make the beginning of treatment more comfortable, ramp time is the period during which the pressure increases from a low start pressure to the treatment pressure. To adjust your ramp time: 1. From your HOME 2.
  • Page 7: Selecting The Mask Type

    S9 Essentials S9 Essentials is designed to make device interaction and menu navigation easier for you. If enabled by the clinician, S9 Essentials disables the Info and Setup functionality so that you can simply start and stop therapy and adjust ramp, humidification and Climate Control. Selecting the mask type To select your type of mask: 1.
  • Page 8: Getting Started

    Getting started 1. Make sure the power is connected. 2. Adjust the ramp time if required. 3. Fit your mask as described in your mask user guide. 4. To start therapy, simply breathe into the mask and/or press 5. Lie down and arrange the air tubing so that it is free to move if you turn in your sleep.
  • Page 9: Viewing The Treatment Screens

    Viewing the treatment screens Depending on how the system has been configured, you will see one of the following example screens (shown in the VAuto mode) once therapy has started: 9 H5i humidifier 9 H5i humidifier 9 H5i humidifier 9 ClimateLine or ClimateLine 9 ClimateLine or ClimateLine heated air tube heated air tube...
  • Page 10 To toggle between treatment screens 1 and 2, press from your HOME screen. 9 Treatment with cycle 9 Treatment with spontaneous (Ti Max or Ti Min) breath cycled breaths indicators Viewing the Info menu The Info menu has a series of screens showing your sleep quality, sleep report and service information. To view the Info menu, push from your HOME screen.
  • Page 11: Cleaning And Maintenance

    Replace the air filter every six months (or more often if necessary). 1. Remove the air filter cover from the back of the Auto 25 device. 2. Remove and discard the old air filter. 3. Insert a new ResMed air Air filter cover filter ensuring that it is sitting flat in the air filter cover.
  • Page 12 S9 SD Card Protective Folder provided with your device. Please retain the S9 SD Card Protective Folder for future use. Notes: • For Troubleshooting information refer to the Information Guide. • For more product information see www.resmed.com.
  • Page 14 Boulevard San Diego CA 92123 USA. ResMed locations worldwide. For patent information, see www.resmed.com/ip. S9, H5i, ClimateLine, SlimLine and SmartStart are trademarks of ResMed Ltd and. S9, ClimateLine and SmartStart are registered in U.S. Patent and Trademark Office. © 2013 ResMed Ltd.