PRESTART CHECKLIST

Before starting the unit, all items in the prestart checklist must be completed.
 Read and understand ALL safety sections at the beginning of this manual.
 Ensure all maintenance procedures are up to date. For more information, refer to
Maintenance " on page 24
 The unit must be level.
 The unit must be dry. Check for any water inside, on, or near the unit, dry if needed.
 Ensure the unit is properly grounded to a good earthen ground. Installation should be in compliance
with the National Electrical Code (NEC), as well as any state and local codes or regulations.
 Switch the "CONTROL ON/OFF" toggle switch to "OFF/O".
 Switch all circuit breakers to "OFF/O".
 Inspect all electrical cords; repair or replace any that are cut, worn, or bare.
 Ensure all winch cables are in good condition and centered on each pulley. Do not use if cables are
kinked or beginning to unravel.
 Check oil, coolant, and fuel levels. For more information, refer to
 Ensure engine battery connections are secure.
 Turn the battery disconnect switch on, if equipped.

STARTING THE UNIT

1. Check that the main circuit breaker and individual
circuit breakers for each of the lights are in the "OFF/
O" position.
Note: When the red "TURN MAIN BREAKER OFF" light
is illuminated, the main circuit breaker must be turned
"OFF/O".
2. Turn the key on the Engine Start switch to the left
"GLOW PLUG" position and hold the key in place for
five seconds, or until the glow plug indicator turns
red. (Kubota units do not have a glow plug indicator.)
As soon as it is glowing, turn the key to the right "START" position and hold it until the engine cranks and starts
running. Release the key, it will move to the "RUN" position.
Note: For cold weather conditions, refer to the engine operator's manual for appropriate glow plug interval.
ACTIVATE GLOW PLUG
OFF
GLOW
PLUG
Do not crank the engine longer than 10 seconds at a time. If the engine will not start, wait
30 seconds to allow the starter motor to cool and then repeat the starting procedure.
Note: If oil pressure is not obtained within 15 seconds after the key is switched to the "RUN" position, the low oil
automatic shutdown will turn off the fuel supply, stopping the engine. Check the oil level and turn the key to the "OFF"
position to reset the oil pressure timer before attempting to restart the engine.
3. Once the engine is running, allow it to reach normal operating temperature before switching on any loads.
18
and Basic Maintenance Schedules beginning on
CRANK ENGINE TO START
RUN
GLOW
PLUG
START
Excessive cranking will cause damage to the starter.
"General Maintenance " on page
CIRCUIT BREAKERS
OFF
GLOW
RUN
PLUG
START
"General
page
25.
I
I
I
I
O
O
O
O
RELEASE KEY
OFF
RUN
START
00203
24.
00202

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mlt3060kvMlt3060mv

Table of Contents