Graco President B Series Instructions And Parts List
Graco President B Series Instructions And Parts List

Graco President B Series Instructions And Parts List

Mining 10:1 ratio pump
Hide thumbs Also See for President B Series:

Advertisement

Quick Links

Instructions – Parts List
QUICK KNOCK DOWN PUMP
WITH NON–SPARKING CONSTRUCTION
Mining Pump
10:1 Ratio President Pump
1000 psi (7.0 MPa, 70 bar) Maximum Working Pressure
222167, Series B
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
WARNING
This pump is specially designed with non-sparking
construction. Interchange of any part for repair or
improvement of the pump, including the air motor,
must be with identical parts bearing the same part
numbers given on pages 13–15. To reduce the risk
of a fire or explosion and serious injury, the use of
any other parts is prohibited.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001
307962J
01605

Advertisement

Table of Contents
loading

Summary of Contents for Graco President B Series

  • Page 1 13–15. To reduce the risk of a fire or explosion and serious injury, the use of any other parts is prohibited. 01605 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
  • Page 3 Permanently coupled hoses cannot be repaired; replace the entire hose. D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.
  • Page 4: Fire And Explosion Hazard

    WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing/dispensing immediately.
  • Page 5: Installation

    Installation Grounding 5. Dispensing valve: grounding is obtained through connection to a properly grounded fluid hose and pump. WARNING 6. Fluid supply container: according to your local code. FIRE AND EXPLOSION HAZARD Before operating the pump, ground the 7. Object being sprayed: according to your local code. system as explained below.
  • Page 6: Pressure Relief Procedure

    Operation Pressure Relief Procedure 1. Shut off the air to the pump. Disconnect the air hose to be sure pressure is relieved in the air motor. WARNING 2. If the pump or hose is not clogged and the hose is SKIN INJECTION HAZARD not closed off, fluid pressure will be relieved.
  • Page 7: Pump Assembly

    Operation 3. Supply air to the pump. Always open the air regulator WARNING slowly and then increase pressure gradually until the pump is running smoothly. Use the lowest pressure To reduce the risk of static arcing which could necessary to give the desired results. result in a fire or explosion and serious injury, use To Stop Dispensing only non-sparking tools if the pump is being as-...
  • Page 8 Operation If the Pump Will Not Be Used for Five If the Pump or Hose Clogs Minutes or Longer WARNING 1. Remove the pump from the mixing container. Turn If the pump or the hose clogs, use extreme caution on the air and direct the material flow into the mixing to avoid splashing material in your eyes while container.
  • Page 9: Troubleshooting

    Troubleshooting Before servicing this equipment always make sure to WARNING Relieve the Pressure. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Check all possible problems and solutions before Pressure Relief Procedure on page 6. disassembling the pump.
  • Page 10: Air Motor Service

    Air Motor Service Repairing the Air Motor WARNING CAUTION To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the To reduce the risk of damaging parts: Pressure Relief Procedure on page 6. Use special pliers, Part No. 207579, when handling the trip rod.
  • Page 11: Cutaway View

    Air Motor Service PUSH TOGGLES (B) IN AND THEN UP TURN WIRES UP CUT OFF TOPS OF POPPETS AS INDICATED BY DOTTED LINES 114A 116a 114B 114A 114B 0.145” (3.68 mm) 116c CUTAWAY VIEW Fig 4 NOTE: Refer to Fig. 4 for Steps 5 to 21. 15.
  • Page 12: Displacement Pump Service

    Displacement Pump Service Apply Lubricant WARNING Apply thread sealant. To reduce the risk of static arcing which could Torque rod to housing to 130–150 in–lb. result in a fire or explosion and serious injury, use Torque to 130–150 in–lb. only non-sparking tools if the pump is being as- sembled or worked on in a hazardous atmosphere.
  • Page 13: Displacement Pump

    Parts USE GENUINE GRACO PARTS AND ACCESSORIES DISPLACEMENT PUMP Model 222173, Series C Includes items 1 to 27 PART NO. DESCRIPTION 183934 COLLAR 183918 NUT, lug 183928 COUPLING; cst 222406 PIN, coupling 183932 ROD, displacement; cst 183936 CYLINDER, upper; cst 188739 PACKING, u–cup, upper;...
  • Page 14 Parts PRESIDENT AIR MOTOR PART NO. DESCRIPTION Model 222171, Series B Includes items 101 to 136 156698 O–RING, buna–n 158360 YOKE, rod, trip 158362 PIN, toggle PART NO. DESCRIPTION 158364 ROCKER, toggle 167585 SPRING, compression 207150 TRIP ROD 111* 158367 GROMMET, rubber, 183804 BASE, motor, air...
  • Page 15 Parts PRESIDENT PUMP Model 222167, Series B Includes items 201 to 202 NO. PART NO. DESCRIPTION 201 222171 MOTOR, air, President see parts on page 14 202 222173 PUMP, displacement see parts on page 13 Ref 134 page14 WARNING This pump is specially designed with non-sparking construction.
  • Page 16 Dimensions Mounting Hole Layout 11” (240 mm) 1/2 npt(f)President President President Air Motor FOUR 1/4–20 UNC–2B 3” (76.2 mm) 46.5” (1145 mm) President diameter 1.503” (38.18 mm) 3/4 npt FLUID OUTLET 1.503” 30.5” (775 mm) (38.18 mm) 18” (460 mm) 01605 307962...
  • Page 17 President Pump – Technical Data Pump Motor Ratio ........10:1 Maximum inbound air pressure .
  • Page 18: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

222167

Table of Contents