Cleaning frequency
chart
Cleaning tools and
materials
Opening the scanner
cover
52
A recommended cleaning sequence includes vacuuming the scanner
transport, cleaning the residue from the feed module tires, separation roller
tires and drive rollers and cleaning the imaging guides. Use the chart below as
a guide to how frequently you should clean your scanner.
Procedure
Vacuum output tray and input
areas (input elevator and
transport)
Clean all rollers
Vacuum transport area
Run transport cleaning sheet
Clean imaging guides - basic
Clean imaging guides - thorough
Use only these cleaning tools and materials when performing routine
maintenance on your scanner. Use of any other cleaning materials could
damage your scanner.
Kodak Digital Science Transport Cleaning Sheets
Kodak Digital Science Roller Cleaning Pads
Staticide wipes for Kodak Scanners (Staticide wipes are not available in all
countries)
Brillianize Detailer Wipes for Kodak Scanners
A vacuum cleaner and tools
1. Power down the scanner.
2. Remove any documents from the input elevator, transport and output tray.
3. Pull the scanner cover release latch forward. The scanner cover will open
partially. Raise the cover up to fully open the cover for access to the
internal components.
4. When finished cleaning the scanner or replacing a consumable, close the
scanner cover with both hands.
Start of
Middle of
day
shift
x
x
x
x
x
x
As needed to remove streaks.
A-61837 September 2016
Start of new
shift
x
x
x
x

Advertisement