Section6
Settings for Judgment Output
Setting
ON-DLY
1 SHOT

Assignment of Judgment Output (For Multi-Task)

Sets which TASK to output.
 FUN mode-[I/O SET]-[JUDGE]-[OUTPUT]
Setting
TASK1
TASK2
TASK3
TASK4
When you want to output the judgment of multiple tasks together using Multi-Task mode, you need to
have a real-time parallel output unit.
ZS-HL
6-8
User's Manual
After the measurement result
has been applied, delays turning
ON the PASS output for the time
set to the timer.
Also delays turning OFF the
HIGH and LOW outputs for the
timer time.
Range: 1 to 5,000 (ms)
When the judgment result
changes to PASS, outputs the
PASS output for the time set to
the timer.
Neither the HIGH nor the LOW
output is output.
Range: 1 to 5,000 (ms)
The selected task result is output to the following output lines. (default value:
TASK1)
• HIGH
• PASS
• LOW
• BUSY
Settings for Terminal Block Output p.6-9
Description
Measured value
HIGH threshold value
LOW threshold value
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
Measured value
HIGH threshold value
LOW threshold value
HIGH output
ON
OFF
PASS output
ON
OFF
LOW output
ON
OFF
Description
: Timer time
: Timer time