Refrigeration charge
All service on refrigeration systems must be performed in accordance with all federal, state and local laws. It is
the responsibility of the technician to ensure that these requirements are met. Recharging ice machine to other
than factory specifications will void the warranty.
Attention: Unit must be charged by weight, not by clear sight glass.
R404A ice machine charge specifications for 1810/2110 models with line
Total charge
Condensing unit holding charge
Charge at installation
Note: Condensing unit shipped with 0.5 lb of R404A charge.
Refrigerant replacement requirements
1. Non-contaminated refrigerant removed from any Follett refrigeration system can be recycled and
returned to the same system after completing repairs. Recycled refrigerant must be stored in a clean,
approved storage container. If additional refrigerant is required, virgin or reclaimed refrigerant that
meets ARI standard 700-88 must be used.
2. In the event of system contamination (for example, a compressor burn out, refrigerant leak, presence of
non-condensibles or moisture), the system must be repaired, evacuated and recharged using virgin or
reclaimed refrigerant that meets ARI standard 700-88.
3. Follett LLC does not approve of recovered refrigerants. Improper refrigeration servicing procedures will
void the factory warranty.
Evacuation
Evacuate the system to a level of 500 microns. When the 500 micron level is reached, close all valves. Allow the
system to sit for approximately 20 minutes. During this period the system pressure should not rise. If the system
pressure rises and stabilizes there is moisture in the system and further evacuation is needed. If the pressure
continues to rise check the system for leaks.
Ambients
Air temperature
1
Water temperature
2
1
Ambient air temperature is measured at the air-cooled condenser coil inlet .
2
Ambient water temperature is measured in the ice machine water reservoir .
Ice capacity test
Ice machine production capacity can only be determined by weighing ice produced in a specific time period.
1. Replace all panels on ice machine.
2. Run ice machine for at least 15 minutes.
3. Weigh and record weight of container used to catch ice.
4. Catch ice for 15 or 20 minutes.
5. Weigh harvested ice and record total weight.
6. Subtract weight of container from total weight.
7. Convert fractions of pounds to decimal equivalents (ex. 6 lbs 8oz = 6.5 lbs).
8. Calculate production using following formula:
1440 min. x wt. of ice produced
Total test time in minutes
9. Calculated amount per 24 hours should be checked against rated capacity for same ambient and water
temperatures in Ice Production Tables.
HC_1810R/N, HC_2110R/N, HM_1810R/N, HM_2110R/N
runs of 0 to 75 ft. (0 m to 22.8 m)
Minimum
50 F/10 C
45 F/7 C
=
Production capacity/24 hr.
14.5 lbs (6.57 kg)
0.5 lbs (0.23 kg)
14 lbs (6.35 kg)
Maximum
100 F/37.8 C
90 F/32.2 C
31