Identify A Fault Drive; Rear Drive Module; Removing The 2 X 2.5-Inch Rear Drive Module - Dell XC Core XC760 Installation And Service Manual

Table of Contents

Advertisement

Figure 46. Installing a drive into the drive carrier

Identify a fault drive

Due to the replacement of sg_ses with PERCCLI on the CVM, the drive failure indicator will now blink in green instead of amber
on HBAs, such as the HBA 355. There is no other functional change.

Rear drive module

Removing the 2 x 2.5-inch rear drive module

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3. If required, remove the air shroud.
4. Remove the drives.
5. Disconnect the cables from the rear drive module.
NOTE:
Refer to
cable routing
Table 34. Rear drive bay slot numbers 
Configurations with two rear drives
12 x 3.5-inch SAS/SATA + 2 x 2.5-inch SAS/
SATA
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws that secure the rear drive module to the system.
2. Press the blue release tab and holding the edges lift the rear drive module away from the system.
74