Dual Rough Opening - True RESIDENTIAL TR-30RBF Install Manual & User Manual

Built-in bottom freezer
Table of Contents

Advertisement

DUAL ROUG H OPENING
TR-30RBF / TR-30RBF
Flush installation: The front face of the unit is flush
with the surrounding appliances.
Proud (standard) Installation: The front face of the
unit extends beyond the surrounding appliances.
NO T E: I T I S NO T R EC OMMEND ED T O IN S TA L L
UNI T S SID E BY SID E W I T H HING E S T OUCHING
E A CH O T HER . IF YOU P L A N T O IN S TA L L
UNI T S HING E-T O - HING E , YOU MU S T H AV E A
MINIMUM 1/ 4" (6.3 5 MM ) G A P BE T W EEN T HE
A P P L I A NCE S BEING JOINED HING E-T O - HING E .
1 1/2" 38mm
2 1/2" 64mm
6" 152mm
Page 12 of 56
T RUE RE S ID E N TI A L
S I T E P R E P A R A T I O N
30" 762mm
TR-30RBF
TR-30RBF
12" 305mm
59 1/4" 1505mm
PROUD INSTALL
60 1/4" 1530mm
FLUSH INSTALL
®
09/07/2023
Rough Opening Dimensions
Flush Install
60-1/4"
Width
(1,530.35 mm)
25-25/32"
Depth
(654.84 mm)
84-1/4"
Height
(2139.95 mm)
N O T E: D IMENSI O NS M AY VA RY BY ± 1 / 8 " (3.175 m m)
NO T E: IF JOINING W I T H O R IN S TA L L ING
NE X T T O A NO T HER T RUE C O L UMN O R SB S
A P P L I A NCE , T HE T RUE C O L UMN O R SB S
A P P L I A NCE D O O R MU S T BE SP ECI A L- O R D ER ED
F O R T HE D O O R H A ND L E S T O A L IGN.
8" 203mm
2" 51mm
77" 1956mm
6" 152mm
Proud Install
59-1/4"
(1,504.95 mm)
23-25/32"
(604.04 mm)
83-3/4"
(2,127.25 mm)
84 1/4" 2140mm
FLUSH INSTALL
83 3/4" 2127mm
PROUD INSTALL
TEC_TM_236 REV. A_EN