SAFETY DEVICES AND ALARMS

The product is supplied with the following safety devices

12.1 PRESSURE SWITCH

• It controls pressure in the fume duct. It blocks the pellet feed screw in the following instances:
• clogged exhaust
• Significant negative (wind)
• clogged fume passages
• open pellet loading tank
• open fire door or worn/broken gaskets.
• see SMOKE RPM VARIATION User Manual

12.2 SMOKE TEMPERATURE PROBE

Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the
preset value.

12.3 CONTACT THERMOSTAT IN THE FUEL HOPPER

If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.

12.4 ELECTRICAL SAFETY

The product is protected against sudden current surges by a main fuse in the power supply panel on the rear part of the product.
Other fuses that protect the electronic boards are found on the latter.

12.5 SMOKE FAN

If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.
24
Stufe a pellet
Used batteries contain metals which are harmful for the environment; they must therefore be disposed of
separately in the special containers.
Fig. 30 - Remote control
LEGEND
Fig. 30
Button 1
Increase the desired temperature (5÷35 °C)
Button 2
Decrease the desired temperature (35÷5 °C)
Button 3
On / off
Button 4
Menu
Button 5
Decrease the power level from 5 to 1
Button 6
Increase the power level from 1 to 5

Advertisement

Table of Contents
loading

Table of Contents