Pellets Recipe; Pag. 13); Smoke Rpm Variation; Menu A Pag. 13) - Cadel Cristal 7 Up User Manual

Hide thumbs Also See for Cristal 7 Up:
Table of Contents

Advertisement

8.17 PELLETS RECIPE (SEE SECTION H SETTINGS MENU A PAG. 13)
Changes to be made with the support of the authorised technician.
Activates only with the Easy Set function disabled, "SET: 0" !
This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of pellets on the market,
boiler operation is extremely variable depending on the fuel quality. In the event the pellets tend to clog the brazier due to an
excessive load of fuel or in the event the flame is always high even at low powers and, vice versa if the flame is low one can decre-
ase/increase the amount of pellets in the brazier:
The available values are:
-30= 30% reduction with respect to the default setting.
-25= 25% reduction with respect to the default setting.
-20= 20% reduction with respect to the default setting.
-15 = 15% reduction with respect to the default setting.
-10= 10% reduction with respect to the default setting.
-5= 5% reduction with respect to the default setting.
0= No variation.
+5= 5% increase with respect to the default setting.
+10 = 10% increase with respect to the default setting.
+15 = 15% increase with respect to the default setting.
8.18 SMOKE RPM VARIATION (SEE SECTION I SETTINGS MENU A PAG. 13)
Changes to be made with the support of the authorised technician.
Activates only with the Easy Set function disabled, "SET: 0" !
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the smoke and ash expulsion
speed can be increased. This change resolves all the potential problems related to pellets clogging in the brazier and deposits
forming at the bottom of the brazier itself caused by poor quality fuel or fuel that produces a lot of ashes. The values available are
from -27% to +27% with variations of 3 points at a time. The variation in negative can be used in case the flame is too low.
8.19 CHIMNEY SWEEP FUNCTION (FOR MAINTENANCE TECHNICIANS ONLY) - SEE SECTION K SET-
TINGS MENU A PAG. 13
This function can be activated only when the boiler is on and with power output and heating operation power with parameters
P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections must be taken into account. This status lasts
20 minutes, the countdown is displayed on the panel. At any time the technician can interrupt this stage by quickly pressing the
on/off key.
21
Stufe a pellet
LEGENDA
Fig. 23
A
Smoke Outlet
B
Combustion Air Intake
T
Inspection cap

Advertisement

Table of Contents
loading

Table of Contents