Safety Devices And Alarms; Safety Devices; Pressure Switch; Smoke Temperature Probe - Cadel SWEET3 7 User Manual

Hide thumbs Also See for SWEET3 7:
Table of Contents

Advertisement

11

SAFETY DEVICES AND ALARMS

11.1 SAFETY DEVICES

The product is supplied with the following safety devices

11.2 PRESSURE SWITCH

• It controls pressure in the fume duct. It blocks the pellet feed screw in the following instances:
• - clogged exhaust
• - Significant negative (wind)
• - clogged fume passages
• - open pellet loading tank
• - open fire door or worn/broken gaskets.

11.3 SMOKE TEMPERATURE PROBE

Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the
preset value.

11.4 CONTACT THERMOSTAT IN THE FUEL HOPPER

If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.
Stufe a pellet
Used batteries contain metals which are harmful for the environment; they must therefore be
disposed of separately in the special containers.
Fig. 24 - Remote control
LEGEND
Fig. 25
Button 1
Increase the desired temperature (5÷35 °C)
Button 2
Decrease the desired temperature (35÷5 °C)
Button 3
On / off
Button 4
Menu
Button 5
Decrease the power level from 5 to 1
Button 6
Increase the power level from 1 to 5
19

Advertisement

Table of Contents
loading

Table of Contents