Technical Documentation For Local Space Heaters According To Commission Regulations (Eu) 2015/1185 - (Eu) 2015/1186 (Product Fiche) - Cadel Cristal 7 Up User Manual

Hide thumbs Also See for Cristal 7 Up:
Table of Contents

Advertisement

15
TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM-
MISSION REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Manufacturer
Trademak: model identifier
Description
Indirect heating functionality
Direct heat output
Indirect heat output
CPR harmonised standard
Notified body
Preferred fuel (unique)
η
s
EEI
Energy Efficiency Class (A++ to G scale)
Space heating emissions at nominal heat output
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
Heat output
Useful efficiency (NCV as received)
Auxiliary electricity consumption
Type of heat output/room temperature control (select
one)
Other control options (multiple selections possible)
Permanent pilot flame power requirement
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the
product.
Issue date: 01.12.2021
32
Stufe a pellet
CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
CADEL: SWEET3 7.0 - PERLA3 7.0 - CRISTAL 7.0
FREEPOINT: ONE AIRTIGHT - BEAM AIRTIGHT - ACCENT AIRTIGHT - AC-
CENT K AIRTIGHT- INDIGO EVO 7
PEGASO:VERA 7.0 - LORD7.0
Pellet stove
No
7 kW
- kW
EN 14785
IMQ Spa (N.B.0051)
Compressed wood with moisture content < 12 %
Wood logs with moisture content ≤ 25 %
Other woody biomass
PM (al 13% O
)
2
OGC (al 13% O
)
2
CO (al 13% O
)
2
NO
(al 13% O
)
x
2
PM (al 13% O
)
2
OGC (al 13% O
)
2
CO (al 13% O
)
2
NO
(al 13% O
)
x
2
Nominal heat output (P
)
nom
Minimum heat output (indicative) (P
Useful efficiency at nominal heat output (η
Useful efficiency at minimum heat output (indicative)
)
th,min
At nominal heat output (el
)
max
At minimum heat output (el
min
In standby mode (el
)
sb
Single stage heat output, no room temperature control
Two or more manual stages, no room temperature
control
With mechanic thermostat room temperature control
With electronic room temperature control
With electronic room temperature control plus day
timer
With electronic room temperature control plus week
timer
Room temperature control, with presence detection
Room temperature control, with open window detec-
tion
With distance control option
Pilot flame power requirement (if applicable) (P
)
min
)
th,nom
0,049
0,023
)
0,002
)
pilot
YES
NO
NO
86
%
126
-
A+
15
mg/Nm
3
1
mg/Nm
3
42
mg/Nm
3
117
mg/Nm
3
20
mg/Nm
3
4
mg/Nm
3
238
mg/Nm
3
140
mg/Nm
3
7
kW
2,5
kW
90
%
91
%
kW
kW
kW
NO
NO
NO
NO
NO
YES
NO
NO
NO
N.A.
kW

Advertisement