ABNORMAL FLAME PATTERN

Each Rinnai Gas Fire has a distinct flame pattern. The flame should look the same every time you operate your
heater, after an initial warm up period of approximately 15 minutes.
Abnormal flame performance and/or pattern can indicate a problem with your heater, such as blocked gas injectors,
incorrectly installed / inadequate flue system or the Ceramic logs / stones and/or burner media may have shifted.
There are some warning signs that could indicate a problem. If any of the signs below occur, please contact Rinnai.
Key signs of abnormal flame performance:
NORMAL FLAME PATTERN
Appliance turns 'OFF' soon after start up and does not relight.
Flame appears overly orange-yellow.
Flame appears either very short or very long.
Flame only burns part way across the burner.
Severe soot building up on the inside of the glass or on logs.
Continuous unusual smell from the appliance.
Continued difficulty or delay in establishing a flame.
Be advised that appliances with a live fuel effect, designed to operate with luminous flames, may
exhibit slight carbon deposition. This is normal operation.