Flow Control
Selects the flow control to be used for console redirection. Options are None,
Hardware and Software.
Redirection After BIOS POST
This option sets redirction after BIOS POST. Options are Disable (no redirection
after BIOS POST), Boot Loader (redirection during POST and during boot loader)
and Always (redirection always active). Note that some OS's may not work with
this set to Always.
Terminal Type
Selects the type of the target terminal. Options are ANSI, VT100 and VT-UTF8.
VT-UTF8 Combo Key Support
Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/
VT100 terminals.
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information.
Options are No Delay, 1 sec, 2 secs and 4 secs.
 Hardware Health Configuration
CPU Overheat Alarm
This setting allows you to specify the type of alarm for CPU overheating. Options
include The Early Alarm and The Default Alarm.
Fan Speed Control
This feature allows the user to determine how the system will control the speed
of the onboard fans. The options are Full Speed/FS (Max Cooling), Performance/
PF (Better Cooling), Balanced/BL (Balance between performance and energy
saving), Energy Saving/ES (Lower Power and Noise).
Other items in the submenu are systems monitor displays for the following
information:
CPU 1 Temperature, CPU 2 Temperature, System Temperature, Air Tempera-
ture, Fan 1-8 Reading, CPU 1 VCore, CPU 2 VCore, CPU 1 DDR3 Memory,
CPU 2 DDR3 Memory, CPU 1 Memory Vref 0.75V, CPU 2 Memory Vref
0.75V, SR5690 Core Power P1V1, 1.8V, 5V, 12V, 3.3V, 3.3V STB, Battery
3.0V and CPU 1 1.2V.