A+ SERVER 2022TC-HTRF4 USER'S MANUAL
6-6

System Fans

Four fans circulate air through the chassis to lower the internal temperature. They
are not hot-swappable. No tools are required for installation.
Changing a System Fan
1. If necessary, open the chassis while the power is running to determine which
fan has failed. (Never run the server for an extended period of time with the
chassis cover open.)
2. Remove the failed fan's power cord from the backplane.
3. Lift the fan housing up and out of the chassis.
4. Push the fan up from the bottom and out of the top of the housing.
5. Place the replacement fan into the vacant space in the housing while making
sure the arrows on the top of the fan (indicating air direction) point in the
same direction as the arrows on the other fans (Figure 6-4).
Figure 6-4. Replacing a System Fan in the Fan Housing