Checking The Airflow; System Fans; Optional Fan Configurations - Supero SUPERSERVER 2027TR-D70RF User Manual

Table of Contents

Advertisement

6-5

Checking the Airflow

Checking Airflow
1. Make sure there are no objects obstructing the airflow in and out of the
chassis. In addition, if you are using a front bezel, make sure the bezel's filter
is replaced periodically.
2. Except for brief periods while swapping hard drives, do not operate the server
without drives or the drive carriers in the drive bays. Use only recommended
server parts.
3. Make sure no wires or foreign objects obstruct airflow through the chassis.
Pull all excess cabling out of the airflow path or use shorter cables.
4. The control panel LEDs inform you of system status. See "Chapter 3: System
Interface" for details on the LEDs and the control panel buttons.
6-6

System Fans

Four fans provide cooling for the chassis. These fans circulate air through the
chassis as a means of lowering the chassis internal temperature. The SC217HD
system fans are easy to change modules. There is no need to uninstall any
other parts inside the system when replacing fans, and no tools are required for
installation.

Optional Fan Configurations

The SC217HD chassis is designed with a hot-swappable fan configuration. One fan
is connected directly to each serverboard. In the event that one of the node drawers
is removed, then the fan associated with that serverboard will not function until the
drawer is replaced. If multiple controls are desired in the SC217HD, an optional
cable must be purchased separately to connect from the backplane to each node.
Fan Configurations
Hot-Swappable Fan Default Configuration
Fans A and B connected to backplane,
backplane connected to Node A and B by adapter card
6-5
Chapter 6: Advanced Chassis Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 2027tr-d70rf+

Table of Contents