11 - OPTIONS AND ACCESSORIES
Options
Dry-cooler control
Energy Management Module
SmartVu
control, 7" user
TM
interface
Dual relief valves on 3-way
valve
Compliance with Swiss
regulations
Compliance with Russian
regulations
Compliance with Australian
regulations
Low noise level
Welded evaporator
connection kit
Welded condenser water
connection kit
Flanged evaporator water
connection kit
Flanged condenser water
connection kit
Thermal compressor
insulation
Compliance with Morocco
regulation
Free-cooling dry-cooler
control
Low GWP A1 R-515B
refrigerant
30
Description
Adaptation of the control box for
communication with the dry-cooler via a bus.
154
For dry cooler need to select the cabinet
with option control cabinet manage by the
chiller control
EMM Control board with additional inputs/
156
outputs. See Energy Management Module
option chapter
Control supplied with a 7 inch colour touch
158A
screen user interface
194 Three-way valve upstream of dual relief valves
on the evaporator and the oil separator
Additional tests on the water heat exchangers:
supply (additional of PED documents)
197
supplementary certificates and test 
certifications
199 EAC certification
200 Unit approved to Australian code
257 Evaporator sound insulation
266 Victaulic piping connections with welded joints Easy installation
267 Victaulic piping connections with welded joints Easy installation
268 Victaulic piping connections with flanged joints Easy installation
269 Victaulic piping connections with flanged joints Easy installation
The compressor is covered with a thermal
271
insulation layer
Specifics documents according Morroco 
327
regulation
Control & connections to a Free Cooling
313
Drycooler 09PE or 09VE fitted with option
FC control box
330 Unit delivered with R-515B refrigerant charge
(A1, GWP 299)
Advantages
Easy system management, extended
control capabilities of a remote dry-cooler
Extended remote control capabilities
(Set-point reset, ice storage end, demand
limits, boiler on/off command...)
Enhanced ease of use.
Valve replacement and inspection
facilitated without refrigerant loss.
Comforms to European standard EN378/
BGVD4
Conformance with Swiss regulations
Conformance with Russian regulations
Conformance with Australian regulations
3 dB(A) quiter than standard unit
Prevents air humidity to condensate on the
compressor surface
Conformance with Morocco regulations
Easy system managment, Extended
control capabilities to a dryccoler used in
Free Cooling mode
Reduced CO
footprint (GWP < 300)
2
A1 safety class
Reduced installed cost in technical room
Use for
30XW-PZE
range
301-1101
301-1101
301-1101
0301-1101
301-1101
0301-1101
301-1101
401-1101
301-1101
301-1101
301-1101
301-1101
301-1101
0301-1101
301-1101
0301-1101