onto the terminal stud. The nut should be able to spin freely with your fingers when it
is first placed onto the terminal stud. Applying installation torque to the nut when it is
improperly threaded might result in damage to the terminal stud.
CAUTION: The maximum torque rating of the terminal studs on the DC power supply
is 36 lb-in. (4.0 Nm). The terminal studs might be damaged if excessive torque is
applied. Use only a torque-controlled driver or socket wrench to tighten nuts on the
DC power supply terminal studs.
4. Connect each DC power cable to the appropriate external DC power source.
NOTE: For information about connecting to external DC power sources, see the SRX5600
Firewall Hardware Documentation at www.juniper.net/documentation/.
5. Switch on the power supply breakers to provide voltage to the DC power source cable leads.
Proceed to
"Step 7: Perform the Initial Software Configuration" on page

Step 7: Perform the Initial Software Configuration

IN THIS SECTION
Enter Configuration Mode | 22
Configure User Accounts and Passwords | 22
Configure System Attributes | 23
Commit the Configuration | 24
This procedure connects the firewall to the network but does not enable it to forward traffic. For
complete information about enabling the firewall to forward traffic, including examples, see the
appropriate Junos operating system (Junos OS) configuration guides at www.juniper.net/techpubs/.
To configure the software: