1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the
CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice or pilot.
nd
2. Between a 2
family gas (G20 or G25) and a 3
a. Change the orifices.
b. Change the pilot.
c. Change the gas valve regulator or the gas valve.
d. Adjust the manifold pressure.
3. Affix the new label included with the conversion kit next to the existing rating plate stating that
the gas type has been converted. Remove any references to the previously used gas from the
existing rating plate.
4. If the destination language changes, replace the labels. Call your local service agency or kitchen
equipment supplier for a label kit. The language of reference will be on the corner of the label.
The following CE gas-conversion components and kits are available from your FAS:
Model 35 Only: There are no CE conversion kits available for the Model 35. Honeywell G31 (propane)
gas valves can be adjusted for G20 and G25 (natural) gases, but G20 and G25 gas valves cannot be
adjusted for G31. Therefore, if converting from a G20 or G25 gas to G31 gas, in addition to the pilot and
orifices, the gas valve must be changed. The table below identifies the parts required to convert from one
gas family to another:
Propane (G31) to Natural (G20/G25)
Regulator only: P/N 810-1292
Pilot, regulator, and orifices kits:
P/N 826-1203 (Model 45)
Natural (G20/G25) to Propane (G31)
Regulator only: P/N 810-1292
Pilot, regulator, and orifices kits:
P/N 826-1202 (Model 45)
nd
2
Family (G20/G25) to 3
826-1354 (package of 10 burner orifices)
810-0427 pilot orifices (2 Required)*
807-2121 CE Gas Valve (Millivolt)
*Quantity required is one unless otherwise noted.
CE Gas Conversion Instructions
rd
rd
Family (G31)
2-11
family gas (G31 Propane):
rd
3
Family (G31) to 2
826-1353 (package of 10 burner orifices)
810-0426 pilot orifices (2 Required)*
Adjust Gas Valve (No Replacement Required)*
Conversion rating label PN 802-2144
nd
Family (G20/G25)