Download Print this page

Frymaster MJ45 Installation, Operation And Maintenance Manual page 17

Hide thumbs Also See for MJ45:

Advertisement

appliance movement. If a flexible gas hose is used, a restraining cable must be connected at all
times when the fryer is in use. The restraining cable and installation instructions are packed with
the flexible hose in the accessories box that was shipped with your unit.
2. Single unit fryers must be stabilized by installing restraining chains on fryers equipped with
casters or anchor straps on fryers equipped with legs. Follow the instructions shipped with the
casters/legs to properly install the chains or straps.
Do not attach an apron drain board to a single fryer.
unstable, tip over, and cause injury. The appliance area must be kept free and clear
of combustible materials at all times.
Level fryers equipped with legs by screwing out the legs approximately 1 inch, and then adjust them
so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the
minimum distance from the flue outlet to the bottom edge of the filter be 24 inches (600 mm) when
the appliance consumes more than 120,000 BTU per hour.
3. For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryer
is to be installed must be level.
4. Test the fryer electrical system: Verify correct voltage and connect per National codes and
regulations.
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
 For fryers equipped with thermostat controls, verify that the power and heat lights are lit.
 For fryers having computer or digital displays, verify that the display indicates CYCL..
c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are
out, or that the display is blank.
5. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is configured
for the proper type of gas before connecting the gas line quick-disconnect device or piping from
the gas supply line.
6. Verify the minimum and maximum gas supply pressures for the type of gas to
be used in accordance with the accompanying tables:
7. For fryers equipped with a built-in filter system and/or basket lifts, plug the
electrical cord(s) into a power receptacle behind the fryer.
Non- CE Standard for Gas Pressure
Gas Type
Min Pressure W.C/kpa/mbar
Max Pressure W.C/kpa/mbar
Orifice Size (mm)
Number of Orifices
Manifold Pressure (WC)
DANGER
Model 35/GF16FR
Nat
LP
6/1.49/14.93
11/2.74/27.37
14/3.48/34.84
14/3.48/34.84
1.7
1.05
9
9
4.0
10.0
2-6
The fryer may become
NOTE: Gas 
specifications are 
included on appliance 
data plate located 
inside the door. 
Model 45
Nat
LP
6/1.49/14.93
11/2.74/27.37
14/3.48/34.84
14/3.48/34.84
1.45
0.86
18
18
3.0
8.25