The floor load created by the tumble dryer is concentrated and transferred to the installa-
tion surface via the screw feet. A base is not required. However, an uneven floor surface
must be compensated for.
(19 11/16")
> 300
(> 11 13/16")
PDR 514/518/522/914/918/922
x
55 1/8" (1,400 mm)
y
35 11/16" (906 mm)
z
PDR 514/914: 33 9/16" (852 mm)
PDR 518/918: 40 3/4" (1,035 mm)
PDR 522/922: 45 13/16" (1,164 mm)
To facilitate any future maintenance work, a maintenance corridor with a width of at least
19 11/16" (500 mm) must be set up behind the machine and must be accessible at all
times. The distance between the machine and any walls must not fall below the specified
minimum values.
28
(24 13/16")
PDR 528/544/928/944
64 9/16" (1,640 mm)
47 1/2" (1,206 mm)
PDR 528/928: 40 1/16" (1,018 mm)
PDR 544/944: 54 1/2" (1,384 mm)