Specifications

Product No.
Applicable fluid
Rated pressure range
Display/set pressure range
Display/min. set unit
Proof pressure
Used as switch output device
Used as IO-Link device
Current consumption
Protection
Display accuracy
Repeatability
Temperature characteristics
o
(25
C standard)
Output type
Output mode
Switch operation
Maximum load current
Maximum applied voltage
Internal voltage drop
(Residual voltage)
1
Delay time
Hysteresis mode
Window comparator mode
Short circuit protection
3
Unit
Display type
Number of displays
Display colour
Number of display digits
Operation light
4
Digital filter
Liquids and gases do not corrode the parts in contact with fluid
12 to 24 VDC ±10% with 10% voltage ripple or less
18 to 30 VDC, including ripple (p-p) 10%
Polarity protection
±2%F.S.±1 digit (at ambient temperature 25±3
Select from NPN or PNP open collector output.
Select from hysteresis, window comparator,
error output or switch output OFF.
Select from normal output or reversed output.
30 V (during NPN output)
1.5 V or less (Load current 80 mA)
(delay time available for anti-chattering function:
Variable at 0 to 60 s/0.01 step)
Variable from 0
MPa, kgf/cm
3-screen display (Main display, sub display x 2)
Main display: Red/Green, Sub display: Orange
Main display: 4 digits (7-segments)
Sub display: 4 digits (Upper 1 digit 11-segments, 7-segments for other)
LED is ON when switch output is ON (OUT1, OUT2: Orange)
Variable at 0 to 30 s/0.01 step
-83-
ISE79S
0 to 50.0 MPa
-2.5 to 52.5 MPa
0.1 MPa
75 MPa
35 mA or less
±0.5%F.S.
±5%F.S.
80 mA
2.0 ms or less
2
Provided
2
, bar, psi
LCD
No.PS※※-OMY0007-B
o
C)

Advertisement