Definition And Terminology - SMC Networks ISE79S L2 Series Operation Manual

High-precision digital pressure switch
Table of Contents

Advertisement

■Definition and terminology

Term
A
Auto-preset
B
Bottom value display (mode)
C
Chattering
Chattering prevention function
D
Delay time
digit (Min. setting unit)
Digital filter
Display accuracy
Display colour
Display resolving power
Display value fine adjustment
(function)
E
Error displayed
Error output
Performs pressure setting automatically by detecting the increase and
decrease in pressure. For example, if this function is used for a suction test,
the pressure setting will be completed by performing suction and release of
the workpiece.
Shows the minimum pressure from when the power was supplied to the
current time.
The problem of the switch output turning ON and OFF repeatedly around the
set value at high frequency due to the effect of pulsation.
A function to delay the response time of switch output in order to prevent
chattering.
The setting time from when the pressure applied to the pressure switch
reaches the set value, to when the ON-OFF output actually begins working.
Delay time setting can prevent the output from chattering.
Shows how precisely the pressure can be displayed or set by the digital
pressure switch. When 1 digit = 0.1 MPa, the pressure is displayed in
increments of 0.1 MPa, e.g., 0.1, 0.2, 0.3, ..., 49.9, 50.0.
Function to add digital filtering to the fluctuation of pressure value. Smooth the
fluctuation of displayed value for sharp start up or fall of the pressure.
When the function is valid, digital filtering is reflected to the ON/OFF of the
switch output.
Output chattering or flicker in the measurement mode display can be reduced
by setting the digital filter.
The response time indicates when the set value is 90% in relation to the step
input.
Shows The maximum deviation between the displayed pressure value and
the true pressure.
Indicates the colour of the number of digital display. Always green, always
red, green (switch OFF) → red (switch ON), red (switch OFF) → green (switch
ON) are available.
Indicate in how many the rated pressure range can be divided to display.
(Example: When the value can be displayed down to 0.1 MPa for the product
for 0 to 50 MPa, the resolution is 1/500)
Displayed pressure value can be adjusted within the range of 5%R.D. (5%
of displayed value). It is used if the true pressure value is known, or to
eliminate differences between the displayed values of different instruments
that are measuring the same pressure.
The code number displayed, identifying the error detected by the
self-diagnosis function of the pressure switch.
Refer to "Error indication function" on page
Switches the switch output to ON/OFF when an error is displayed.
Refer to "List of output modes" on page
Refer to "Error indication function" on page
-12-
Definition
82
for details of the errors.
32
for operating conditions.
82
for details of the errors.
No.PS※※-OMY0007-B

Advertisement

Table of Contents
loading

Table of Contents