Introduction to State Analysis
Set Up Level 2 of the State Trigger Specification
Set Up Level 2 of the State Trigger Specification
In sequence level 1 the analyzer stores data before the trigger point. For
sequence level 2, you will tell the analyzer to store any data once the trigger
pattern is found. This will fill the rest of the acquisition memory.
Highlight the
1
key.
Highlight the field to the right of
2
Highlight
Press the
3
Once the trigger pattern
is found, the logic
analyzer will store any
data that it samples.
Setting Up Level 2 of the State Trigger Specification
Result
The State Trigger Specification is now:
If your trigger specification does not match this one, repeat the exercises,
starting with "Modify Channel Assignments" on page 3–7.
3-10
2
field in the State Sequence Levels box. Press the
anystate
in the pop-up menu, and press the
Done
key to close the Sequence Level 2 pop-up menu.
Level 1 - While storing "anystate", TRIGGER on "b" 1 time
Level 2 - Store "anystate"
Get other manuals https://www.bkmanuals.com
, and press the
Store
Select
Done
key.