Cn I/F Connector (For Controller - Panasonic MSDA043A1A Operating Manual

Ac servo motor driver
Table of Contents

Advertisement

List of Available Components
CN I/F Connector (For Controller)
Wiring Instructions
3m以内
制御
装置
30cm以上
電源部
モータ
COM+
VDC
COM-
FG
● CN I/F Connector Specifications
Receptacle on the
driver side
10250-52A2JL
・The CN I/F pins assignment is shown in "Optional Parts" in Appendix.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
ID
MODE
SET
IM
SP
G
SER
IN
L 1
SER
OUT
L 2
L 3
I/F
r
t
P
B 1
B 2
SIG
U
V
W
1
2
GND
o
p
GND
アナログ
GND
CN I/F
Connector to controller side
Part description
Solder type plug
Shell
− 28 −
Displace the peripheral devices such as
the controller max. 3 m away from the
driver.
Separate these wiring min. 30 cm from
the main circuit wires.  Don't  lay  these
wires in the same duct of  the
 mains or bundle with them.
The control power (VDC) between COM+ and
COM- should be supplied by the customer
(recommended voltage: +12VDC to +24VDC).
Control signal output terminals can accept
max. 24V or 50mA: Don't apply larger voltage
or current exceeding these limits.
  If you directly activate a relay using the control
signal, install a diode in parallel to the relay as
shown in the left figure. Without a diode or with
it but placed in the opposite direction, the driver
will be damaged.
 Use a shielded twist-paired type for the
wiring of pulse input, encoder signal
output or analog command input.
The Frame Ground (FG) is connected to
an earth terminal in the driver.
Part No.
10150-3000VE
10350-52A0-008
Manufacturer
by Sumitomo 3M

Advertisement