Program Port Dip Switch - Baud Rate Settings - AMX NetLinx NXM-MHS Instruction Manual

Master cards and modules
Table of Contents

Advertisement

Product Information - NetLinx Modules
NXM-MHS Specifications (Cont.)
Front Panel Components Cont.):
Input LED
Front Panel LEDs -
blink patterns
Program Port DIP Switch
Rear Panel Components:
PWR connector
PROGRAM port
ICSNet connectors
ICSNet LEDs
ICSHub In/Out connectors
ICSHub IN/OUT LEDs
AXlink LED
Enclosure
Front Faceplate
Dimensions (HWD):
Card(s)
Module
Optional accessories

Program Port DIP switch - baud rate settings

The Program Port DIP switch is located at the front of the Master Cards. For Modules, you must
remove the front panel to access the DIP Switch.
Use this DIP switch to set the baud rate for the Program Port, according to the settings shown in the
following table. Make sure the baud rate you set matches the baud rate on your PC's COM port
before programming the Master Card. By default, the baud rate is set to 38,400 (bps). Note the
orientation of the DIP Switch and the ON position label.
2
Yellow LED blinks when the Master Card receives data from button
pushes, strings, commands, channel levels, etc.
These LEDs also display special blink patterns when a mode is activated.
See the Modes and front panel LED blink patterns section on page 5 for
details.
8-position DIP switch located behind the front panel for setting the baud
rate for the Program port. The baud rate settings are 9600, 38,400
(default), 57,600 and 115,200 (bps). See the Program Port DIP switch -
baud rate settings section on page 2 for details.
2-pin (male) green captive-wire connector for 12 VDC power supply
5-pin (male) gray connector for system programming and diagnostics.
There is a Program port located on the front and rear of the Master Cards
for easy access. Because these ports share the same circuitry, you
should never use both ports at the same time. Doing so will result in com-
munication and/or programming errors.
Two RJ-45 connectors that provide power (500 mA) and data to external
ICSNet devices
Green LEDs that light when sending/receiving data on that port.
Two RJ-45 connectors that provide data to other Hubs connected to the
Master Card
Yellow LEDs that light when sending/ receiving data on that port.
Green LED shows AXlink/NetLink data activity
Metal with black matte finish
Plastic gray with translucent viewing window
1.5" x 5.0" x 8.8" (45 mm x 127 mm x 224 mm)
5.0" x 4.8" x 8.5" (127 mm x 121.9 mm x 215.9 mm)
• 12 VDC power supply (PSN 6.5, PSN 2.8)
• AC-RK Accessory Rack Kit (Module)
Get other manuals https://www.bkmanuals.com