Figure 57. Removing processor and heat sink module
Next steps
Installing a processor and heat sink module
Removing the non-fabric processor from the processor and heat
sink module
Prerequisites
NOTE:
Only remove the processor from the processor and heat sink module if you are replacing the processor or heat sink.
This procedure is not required when replacing a system board.
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Removing the air shroud
4.
Removing a processor and heat sink module
Steps
1. Place the heat sink with the processor side facing up.
2. Insert a flat blade screwdriver into the release slot marked with a yellow label. Twist (do not pry) the screwdriver to break
the thermal paste seal.
3. Push the retaining clips on the processor bracket to unlock the bracket from the heat sink.