Siemens RUGGEDCOM RSG909R Installation Manual page 37

Hide thumbs Also See for RUGGEDCOM RSG909R:
Table of Contents

Advertisement

RUGGEDCOM RSG909R
Installation Guide
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. When shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more
importantly, create a potential shock hazard that can result in serious injury.
LEDs
Each port features an LED that indicates the state of the port.
Green (Solid)
Green (Blinking)
Off
Pin-Out
The following is the pin-out for the RJ45 male connectors:
8
Figure 25: RJ45 Ethernet Port Pin Configuration
Specifications
For specifications on the available copper Ethernet ports, refer to
Specifications".
Copper Ethernet Ports
State
1
Description
Link established
Link activity
No link detected
Name
Pin
10/100Base-TX
1
RX+
2
RX-
3
TX+
4
Reserved (Do
Not Connect)
5
Reserved (Do
Not Connect)
6
TX-
7
Reserved (Do
Not Connect)
8
Reserved (Do
Not Connect)
Section 5.4, "Copper Ethernet Port
Communication Ports
Description
1000Base-TX
BI_DB+
Receive Data+ or
Bi-Directional
BI_DB-
Receive Data- or
Bi-Directional
BI_DA+
Transmit Data+
or Bi-Directional
BI_DD+
Bi-Directional
BI_DD-
Bi-Directional
BI_DA-
Transmit Data- or
Bi-Directional
BI_DC+
Bi-Directional
BI_DC-
Bi-Directional
Chapter 4