Controller Circuit Board - Kohler 10CCOZ61 Service Manual

Mobile generator sets
Table of Contents

Advertisement

It is possible to check some controller circuit board
components (relays) without removing the component
from the board. These checks should be made prior to
installing a new board and attempting startup. Most of
the tests are referenced in Section 4. General
Troubleshooting. Use a high quality multimeter and
follow the manufacturer' s instructions. To obtain
Component
K1 Relay Coil
K2 Relay Coil
K3 Relay Coil
K4 Relay Coil
K5 Relay Coil
TP-5648 8/93

Controller Circuit Board

Ohmmeter
Connections
K1 coil terminals
(See relay schematic)
K2 coil terminals
(See relay schematic)
K3 coil terminals
(See relay schematic)
K4 coil terminals
(See relay schematic)
K5 coil terminals
(See relay schematic)
Figure 7-7. E-239563 Circuit Board Tests
accurate readings when testing, remove all circuit board
connectors
and
insulation) from component terminals. Use the chart
Figure 7-7 for the controller circuit board layout and
schematic .
Remarks
Ohmmeter on
If good--approx. 160 ohms.
R x 10 scale
Low resistance (continuity)--
shorted coil.
High resistance--open coil.
Ohmmeter on
If good--approx. 160 ohms.
R x 10 scale
Low resistance (continuity)--
shorted coil.
High resistance--open coil.
Ohmmeter on
If good--approx. 400 ohms.
R x 10 scale
Low resistance (continuity)--
shorted coil.
High resistance--open coil.
Ohmmeter on
If good--approx. 125 ohms.
R x 10 scale
Low resistance (continuity)--
shorted coil.
High resistance--open coil.
Ohmmeter on
If good--approx 510 ohms.
R x 10 scale
Low resistance (continuity)--
shorted coil.
High resistance--open coil.
conformal
coating
(transparent
Results
Component Testing and Adjustment 7-9