13. Secure the exciter field to the end bracket using
four screws. Tighten these screws to a torque of
70 in. lbs.
14. Install the end bracket panel and secure it to the
end bracket with six self-tapping screws.
15. Place the junction box atop the generator, routing
the stator leads into the junction box. Secure the
junction box in place using four screws.
16. Reconnect P6 to J6, P7 to J7, and P8 to J8.
17. Place the controller atop the rubber bumpers.
18. Route any external leads into the controller and
secure the ground cable to the controller chassis.
TP-5648 8/93
19. Install the four nuts to secure the controller to the
mounting bumpers.
20. Connect leads from junction box labeled C0, C1,
and C2 to terminals with same labels on controller
chassis. Also connect external leads labeled BAT,
GND, ST1, and ST2 (if used) to terminals with
same labels on controller chassis.
21. Connect 22-pin harness connector J4 to fixed
connector at rear of controller.
22. Reinstall cover on controller and secure by
installing nine screws.