Restart 2S, Restart 4S, Spot and Bi-level
See GTAW section above for details about mode of
working.
Menu SMAW
To enter into Menu SMAW see section Menu, descriped
above
In AC polarity only the HOT Start parameter is visible and
can be changed
Table 11. SMAW Menu
Function
Arc Force
Hot Start
Stick Polarity
ARC FORCE and HOT START
With those two parameters, user can change the
behaviour of unit in STICK DC stick welding. See DC stick
welding for a better understanding of both features.
STICK POLARITY
With this function is possible to change polarity of the
electrode clamp without any change in work cables
connections. For default stick polairity is DC+.
Menu SYS
To enter into Menu SYS see section Menu, descriped
above.
English
Factory Configuration
Default
SOFT: 35%
CRISP: 75%
SOFT: 30%
CRISP: 50%
DC+
Selectable Value Range
0 – 75% (step 1%)
75 – 200% (step 1%)
0 – 75% (step 1%)
50 – 200% (step 1%)
DC+ or DC-
22
Displayed
Displayed
parameter
value
name
Current selected
FRCE
value (%)
Current selected
HSTR
value (%)
Current selected
STPL
value (-)