Lincoln Electric CITOTIG 200 AC/DC Operator's Manual page 20

Table of Contents

Advertisement

List of parameters and Factory stored programs
Table 6. List of parameters and Factory stored programs
Function
Preflow
Starting Current
Initial slope
Operating Amperage
Final Slope
Finishing Current
Post flow
Percent of Peak Current / Duty
Cycle
(Only when pulse function is
enabled)
Pulses-Per-Second DC
(Only when pulse function is
enabled)
Pulses-Per-Second AC
(Only when pulse function is
enabled)
Background Current
(Only when pulse function is
enabled)
SPOT time
(Only when spot function is
enabled)
Low level background
(Only when Bilevel function is
enabled)
Function
EN Offset
EP Offset
AC-Balance
AC-Frequency
English
Factory Configuration
Default
0.5
100
0.1
50
0
30
AUTO
40
0.1
0.1
25
0
25
AC Wave Balance (NOTE D)
Factory Configuration
Default
50
50
75
120
Selectable Value Range
0 - 25s (step 0.1s)
10 – 200 % (step 1%)
0 – 5s (step 0.1s)
TIG PROCESS
2 – 200 A (step 1A)
2- 115A (step 1A) derating
TIG PROCESS
5 – 160 A (step 1A)
5- 110 (step 1A) derating
0 - 25s (step 0.1s)
10 – 90 % (step 1%)
0.1 - 120s (step 0.1s)
Note A
5-95 (step 5%)
Note B
0,1 – 10 Hz (step 0.1Hz)
10 – 500Hz (step 1Hz)
500 – 2000Hz (step 10Hz)
0,1 – 10 Hz (step 0.1Hz)
10 – 100Hz (step 1Hz)
Note C
10 -90 % (step 1%)
0 – 10s (step 0.1s)
10 – 100s (step 1s)
10 -90 % (step 1%)
Selectable Value Range
2 – 200A (step 1A)
2 – 115A (step 1A) derating
2 – 200A (step 1A)
2 – 115A (step 1A) derating
35 – 95 % (step 1%)
40 – 400Hz (step 1Hz)
18
Displayed
Displayed
parameter
value
name
Current selected
PRE
value (s)
Current selected
STRT
value (%)
UP
Current selected
value (s)
Current selected
value (A)
Current selected
DOWN
value (s)
Current selected
END
value (%)
Current selected
POST
value (s)
PEAK
% of FREQ
Current selected
FREQ
value (Hz)
Current selected
FREQ
value (Hz)
BACK
Current selected
value (%)
SPT
Current selected
value (s)
Current selected
A2
value (%)
Displayed
Displayed
parameter
value
name
Current selected
EN
value (A)
Current selected
EP
value (A)
Current selected
%BAL
value (%)
FREQ
Current selected
value (Hz)
English

Advertisement