Lincoln Electric CITOTIG 200 AC/DC Operator's Manual page 21

Table of Contents

Advertisement

Note A: When AUTO is selected means 1s/10A; minimun
value is 3s.
Note B: For frequency value higher than 500Hz, PEAK is
locked to 50%.
Note C: In AC polarity the pulse frequency is limited to ¼
of the AC-frequency: if AC frequency is 120Hz that means
the max pulse frequency is 30Hz . If the pulse frequency
is higher than 1/10 of the AC frequency, the PEAK is fixed
to 50%.
Note D: Once AUTO is selected the default parameter are
used.
Menu GTAW
To enter into Menu GTAW see section Menu, described
above.
The ADVANCED menu part is available only in AC
polarity
Table 7. MENU GTAW Menu
Function
Restart 2S
Restart 4S
Bi-level function
Spot function
English
Factory Configuration
Default
OFF
OFF
OFF
OFF
Selectable Value Range
ON/OFF
ON/OFF
ON/OFF
ON/OFF
19
Displayed
Displayed
parameter
value
name
2RST
Current selected
value (-)
4RST
Current selected
value (-)
Current selected
BILV
value (-)
Current selected
SPOT
value (-)
English

Advertisement

Table of Contents
loading