Flow Control Calibration - Graco ProMix 2KS Operation

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Integrated Flow Control

Flow Control Calibration

Flow Control Calibration is an automatic routine that
establishes a pressure vs flow profile between low and
high operating points. See F
unique to each recipe or may be globally copied to all
recipes.
NOTE: Calibration cannot be done in recipe 0 or 61.
1. Load a color.
2. Go to Advanced Setup Screen 5 (see F
Select the flow rate range that best covers the larg-
est flow target for your application (for example,
0-1200).
F
. 82. Advanced Setup Screen 5 (Automatic Mode
IG
with Flow Control Only)
74
. 86. The profile may be
IG
. 82).
IG
Get other manuals https://www.bkmanuals.com
3. Go to Advanced Setup Screen 1 (see F
Turn Manual Override On.
F
. 83. Advanced Setup Screen 1
IG
4. Go to the Manual Override Screen (see F
Set Manual Override to Mix, and set Flow Ctrl Cali-
bration to Start.
F
. 84. Manual Override Screen
IG
. 83).
IG
.
. 84).
IG
312779E