Automation Flow Charts - Graco ProMix 2KS Operation

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Automation Flow Charts

Start Mix Mode Process
See F
. 65, Table 5, and Table 6.
IG
Must be Alarm Condi-
tion or Active Recipe
61. See Alarm Pro-
cessing on page 59,
or Startup from Rec-
ipe 61 (see NOTE
NOTE: At power up the system
defaults to Recipe 61, which is
not a valid recipe number. Initiate
a color change to Recipe 0 or a
valid recipe number (1-60).
F
. 65. Start Mix Mode Process Flow Chart
IG
312779E
Start Mix
Mode Process
NO
Is Mix Ready
bit = 1?
Get other manuals https://www.bkmanuals.com
ProMix 2KS Integration Specifics
YES
Set Mix bit = 1
NO
Is Mix Active
bit = 1?
YES
ProMix 2KS in Mix
Mode (Complete)
Mix Active = 1 while
the ProMix 2KS is in
Mix mode
55