E-9: MIX IN SETUP ALARM
Cause
Attempt to operate system while in Setup mode.
E-10: REMOTE STOP ALARM
Cause
Automation has requested that the system abort all oper-
ations.
E-11: PURGE VOLUME ALARM
Cause
ProMix 2KS solvent flow switch is not activated while
purging.
Minimum flush volume is not achieved.
No meter pulses during Color/Catalyst Dump.
312779E
Table 17. Alarm Troubleshooting
System must be in Standby to change current recipe,
and cannot be operated.
Abort operations. Troubleshoot automation system.
Verify that the gun is not shut off and that the solvent flow
switch is activated while purge is taking place.
Increase solvent supply or decrease minimum volume
setting.
Color change solvent supply not set up or functional.
Check Color Change setup.