Special Function - Riello SC ACS 40 Manual

Table of Contents

Advertisement

DEFAULT PARAMETER SETTINGS TABLE
NOTE
MENU DESCRIPTION
4. SETTINGS
SET RECIRCULA-
TION PARAME-
TERS
5. PROTECTION FUN-
PROTECTION
6. SPECIAL FUN-
DESCRIPTION
4.1
Tset
4.2
T max.
4.3
VFS type
4.4
Recirculation
4.4.1
Recirculation
4.4.2
Tmin recirculation
Recirculation hyste-
4.4.3
resis
Maximum recircula-
4.4.4
tion flow
4.4.5
Recirculation periods
4.4.6
Draw-off support
Minimum storage
4.4.7
temperature
Draw-off support
4.4.8
calibration
4.13
Comfort
DHW valve period
4.14
responde delay
CTIONS
5.1
Anti-legionella
5.2
Limescale protection
Setpoint auto-regu-
5.3
lation
5.4
Seizing protection
CTION
6.1
Pump V1
6.1.1
Pump type
6.1.2
Pump
6.1.3
Output signal
6.1.4
PWM off
6.1.5
PWM on
6.1.6
PWM max
6.2
Pump speed V1
6.2.1
Max speed
6.2.2
Min speed
6.2.3
Velocità minimun
SETTINGS RAN-
GE
30°C ÷ 85°C
50°C ÷ 95°C
1÷12 / 1÷20 /
2÷40 /
5÷100 / 10÷200 /
200÷400 l/min
on / off
Reques/Periods/
Request+Periods/
Always on
10°C ÷ 85°C
1 ÷ 30 °C
0 ÷ 100 l/min
00:00 ÷ 23:59
on / off
0 ÷ 80°C
on/off
on / off
0 - 2 sec
on / off
on / off
on / off
Daily / Weekly / Off
Primary pump
0 - 10V / PWM
Solar / Heating/
Profile 1-11 /
Manual
Normal / inverted
Solar 0÷50% / He-
ating 87÷100%
Solar 0÷50% /
Heating 50÷98%
Solar 50÷100% /
Heatin 0÷50%
-
15 ÷ 100 %
10 ÷ 95 %
0÷ 5%
25
DEFAULT
USER
SC ACS 40
NOTE
45°C
60°C
2÷40 l/min
off
on if present
periods
35°C
5 °C
15 l/min
06:00 ÷ 20:00
on
65°C
off
off
0
off
off
off
off
-
PWM 1
HEATING
INVERTED
off 98%
on 87%
MAX 7%
-
100%
10%
0%