Clearance Chart And Diagrams - Jøtul Oslo Installation And Operating Instructions Manual

Catalytic wood heater
Table of Contents

Advertisement

139946-18 F 500 V3 Oslo May 2022
Jøtul F 500 V3 Clearances
These clearance specifications result from safety testing by Intertek Testing Services, Inc. Use the table below
together with the diagrams on the facing page to determine the clearances for your particular installation.
Stove clearances result from tests that include the chimney connection in the system.
Chimney connector clearances listed separately are from NFPA 211, independant of the stove position.
Stove Clearance
Stove - no heat shield
Single-wall pipe
Stove with rear heat shields
and single-wall pipe
Stove with rear heat shield
and connector shields
or double-wall pipe
Horizontal Connector Clearance (X)
Single-wall pipe
Double-wall pipe
Fireplace Mantle and Trim Clearance
Stove Side to Side Trim - 1" thick or less:
Stove Top to Upper Trim - 1" thick or less:
Stove Top to Mantle - 12" maximum depth:
Mantel and Trim clearances may be reduced by 50% following protection construction methods specified by NFPA 211 Standards for
Chimneys, Fireplaces, Vent and Solid Fuel Burning Appliances or similar local regulations.
*
Protection specified per NFPA 211.
**
Use of the left side load door is prohibited in Alcove and Corner installations.
Use Side Door Lock Kit # 155850 to permit installation.
22
Unprotected surface
Side
Rear
14" A
18" B
355mm
460mm
14" A
10" G
355mm
255mm
14" A
6" D
355mm
150mm
Unprotected surface
18" 460mm
6" 150mm
12"
300mm
16"
410mm
30"
765mm
Protected surface*
**
Corner
Side
13" C
6" D
330mm
150mm
9" F
6" D
230mm
150mm
9" F
6" D
230mm
150mm
Protected surface*
12"
300mm
6"
150mm
Rear
Corner*
12" E
9" F
300mm
230mm
10" G
9" F
255mm
230mm
6" D
6" D
150mm
150mm
X