Omron D4NL-4AFA-B4 Manual page 8

Guard lock safety-door switch
Table of Contents

Advertisement

Contact Form
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per GS-ET-19).
Model
Contact
D4NL-@AF@-@
1NC/1NO + 1NC/
1NO
D4NL-@BF@-@
1NC/1NO + 2NC
D4NL-@CF@-@
2NC + 1NC/1NO
D4NL-@DF@-@
2NC + 2NC
D4NL-@EF@-@
2NC/1NO + 1NC/
1NO
D4NL-@FF@-@
2NC/1NO + 2NC
D4NL-@GF@-@
3NC + 1NC/1NO
D4NL-@HF@-@
3NC + 2NC
8
Contact form
11
12
41
42
33
34
53
54
11
12
41
42
33
34
51
52
11
12
41
42
31
32
53
54
11
12
41
42
31
32
51
52
11
12
41
42
21
22
53
54
33
34
11
12
41
42
21
22
51
52
33
34
11
12
41
42
21
22
53
54
31
32
11
12
41
42
21
22
51
52
31
32
Operating pattern
Lock position
11-42
33-34
53-54
Stroke
Extraction
Operation
Key insertion
completion
completion
position
position
Lock position
11-42
33-34
51-52
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
31-32
53-54
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
11-42
31-32
51-52
51-52
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
11-42
21-22
21-22
33-34
33-34
53-54
53-54
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
21-22
33-34
51-52
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
21-22
31-32
53-54
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Lock position
11-42
21-22
31-32
51-52
Stroke
Operation
Extraction
Key insertion
completion
completion
position
position
Safety Sensors / Components
Remarks
Only NC contacts 11-
12 and 41-42 have an
approved direct
ON
opening mechanism.
The terminals 11-42, 33-
34, and 53-54 can be
used as unlike poles.
Only NC contacts 11-
12, 41-42, and 51-52
have an approved direct
ON
opening mechanism.
The terminals 11-42, 33-
34, and 51-52 can be
used as unlike poles.
Only NC contacts 11-
12, 31-32, and 41-42
have an approved direct
ON
opening mechanism.
The terminals 11-42, 31-
32, and 53-54 can be
used as unlike poles.
Only NC contacts 11-
12, 31-32, 41-42, and
51-52 have an approved
ON
direct opening
mechanism.
The terminals 11-42, 31-
32, and 51-52 can be
used as unlike poles.
Only NC contacts 11-
12, 21-22, and 41-42
have an approved direct
ON
opening mechanism.
The terminals 11-42, 21-
22, 33-34, and 53-54 can
be used as unlike poles.
Only NC contacts 11-
12, 21-22, 41-42, and
51-52 have an approved
ON
direct opening
mechanism.
The terminals 11-42, 21-
22, 33-34, and 51-52 can
be used as unlike poles.
Only NC contacts 11-
12, 21-22, 31-32, and
41-42 have an approved
ON
direct opening
mechanism.
The terminals 11-42, 21-
22, 31-32, and 53-54 can
be used as unlike poles.
Only NC contacts 11-12,
21-22, 31-32, 41-42 and
51-52 have an
ON
approved direct
opening mechanism.
The terminals 11-42, 21-
22, 31-32, and 51-52 can
be used as unlike poles.