Characteristics
Degree of protection (see note 2)
Durability
Mechanical
(see note 3)
Electrical
Operating speed
Operating frequency
Rated frequency
Contact gap
Direct opening force (see note 5)
Direct opening travel (see note 5)
Holding force (see note 6)
Insulation resistance
Minimum applicable load (see note 7)
Rated insulation voltage (U
i
Rated open thermal current (I
Impulse withstand voltage (EN60947-5-1)
Conditional short-circuit current
Pollution degree (operating environment)
Protection against electric shock
Contact resistance
Vibration resis-
Malfunction
tance
Shock resistance
Destruction
Malfunction
Ambient temperature
Ambient humidity
Weight
Note: 1. The above values are initial values.
2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4NL in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal-
functioning may occur.
3. The durability is for an ambient temperature of 5 ° C to 35 ° C and an ambient humidity of 40% to 70%. For more details, consult your OM-
RON representative.
4. If the ambient temperature is greater than 35 ° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
5. These figures are minimum requirements for safe operation.
6. This figure is based on the GS-ET-19 evaluation method.
7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
D4NL
IP67 (EN60947-5-1)
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
1,000,000 operations min.
500,000 operations min. for a resistive load of 3 A at 250 VAC (see note 4)
0.05 to 0.5 m/s
30 operations/minute max.
50/60 Hz
2 x 2 mm min
60 N min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
1,300 N min.
100 M Ω min. (at 500 VDC)
Resistive load of 1 mA at 5 VDC (N-level reference value)
)
300 V (EN60947-5-1)
)
10 A (EN60947-5-1)
th
Between terminals of the same polarity
Between terminals of different polarities
Between other terminals and uncharged metallic parts
100 A (EN60947-5-1)
3 (EN60947-5-1)
Class II (double insulation)
25 m Ω max. per contact (initial value)
10 to 55 Hz, 0.75-mm single amplitude
1,000 m/s
300 m/s
Operating: − 10 ° C to 55 ° C with no icing
Operating:95% max.
Approx. 370 g (D4NL-IAFA-B)
2
min.
2
2
min. (100 m/s
min. for the lock monitor switch)
2.5 kV
4 kV
6 kV
5

Advertisement

Table of Contents
loading