ATS Custom Category C
EN50136-1:2012 + A1:2018 Table 2 – Transmission time
EN50136-1:2012 + A1:2018 Table 3 – MaximumReporting Time
EN50136-1:2012 + A1:2018 Table 7 – ATSN availability
EN50136- 1:2012 + A1:2018 Table 8 – SPT substitution security
requirements
EN50136- 1:2012 + A1:2018 Table 9 – SPT information security
requirements
EN50136-1:2012 + A1:2018 Table 1 – ATSconfiguration
EN50136-1:2012 + A1:2018 Table 4 – RCT to AEalarmreporting
EN50136-1:2012 + A1:2018 Table 5 – SPT to ASalarmreporting
EN50136-1:2012 + A1:2018 Table 6 – ATSavailabilityrecording
EN50136-2:2013 Table 1
EN50136-2:2013 Table 2
EN50136-2:2013 Table 3
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Tyco Safety ProductsCanada Ltd declaresthat the radio equipment type isin compliance with Directive 2014/53/EU. The fulltext of the EU declar-
ationsof conformityfor the modelsmentioned below are available at the following internet addresses:
TL2803G(R)E-EU -http://dsc.com/pdf/1605003
3G2080(R)E-EU -http://dsc.com/pdf/1605004
TL280LE-EU -http://dsc.com/pdf/2112001
LE2080-EU -http://dsc.com/pdf/2112002
Operating frequency bands and related max radio-frequency power transmitted:
NOTE: The compatible receiver at ARC location shallhave supervision window programmed for 180 seconds. TL2803G(R)E-EU/3G2080(R)E-EU/TL280 (R)
E/ TL280LE- EU/LE2080-EU has been certified by TELEFICATION in accordance with EN50131-1:2006/A2:2017, EN50131- 10:2014 requirements for
Grade 2, ClassII and EN50136-2:2013 ATSCustomCategoryC according to SP4 and DP3.
Frequency Band
EGSM900 890.0MHz- 914.8MHz
EGSM900 880.2MHz-889.8MHz
DCS1800 1710.2MHz-1784.8MHz
WCDMA(Band VIII) 882.4MHz- 912.6MHz
WCDMA2100 (Band I) 1922.4MHz- 1977.6MHz Class3 (0.25W) @ 900/2100MHz, WCDMA
LTE25dBm
OnlymodelsTL2803GRE-EU, TL2803GE-EU, 3G2080RE-EU, 3G2080E-EU, TL280LE-EU and LE2080-EU are CEcompliant.
European single point of contact: Tyco SafetyProducts, Voltaweg 20, 6101XK, Echt, Netherlands
UL/ULC Installation Requirements
NOTE: For equipment used at the protected premisesand intended to facilitate IPcommunications(hubs, routers, NIDs, DigitalSubscriber Line (DSL), cable
modems), 24 hour backup power isrequired. Where such cannot be facilitated, a secondary(back-up) communication channelisrequired.
Domain Name Service (DNS) programming is not permitted in UL1610 listed systems.
Technical Specifications
The input voltage to the Communicator can be drawn fromthe UnderwritersLaboratories/UnderwritersLaboratoriesCanada (UL/ULC) listed controlpanel.
Notes for using Private, Corporate, and High Speed Data Networks:
Networkaccessand domain access policiesshall be set to restrict unauthorized network access, and spoofing or Denialof Service (DoS) attacks. Select an
Internet Service Provider (ISP) that has redundant servers/systems, back-up power, routers with firewalls enabled, and methods to identify and protect
against DoSattacks(e.g., via spoofing).
Notes for using Public Switched and Cellular Data Networks:
Communication channels shall be facilitated such that the communicator willrestrict unauthorized access, which could otherwise compromise security. The
communicator shallbe located in a secured area.
•For ULC Residential Fire and Burglary applicationsthe TL2803G(R)E/3G2080(R)E/TL280(R)E/LE2080(R) /TL280LE(R) can be used asprimary com-
munication channel via either cellular or Ethernet or as a back-up in conjunction with the Digital AlarmCommunicator Transmitter (DACT). Test transmission
every24 hoursshallbe enabled on each channel.
•For ULC Commercial Fire and Burglary applicationsthe TL2803G(R)E/3G2080(R) E/TL280(R)E/LE2080(R) /TL280LE(R) can be used asa passive
communication module with the following securitylevels:
P1 (each channelcellular or Ethernet isindependent)
l
P2 (cellular and Ethernet in back-up configuration, panelsection [851][005] toggle option [5] OFF).
l
P3 (cellular and Ethernet in redundant configuration, panelsection [851][005] toggle option [5] ON).
l
The communicator can also be used as an active communication systemwith the security levels A1-A4 (each channelcellular or Ethernet independent or
together in a back-up/redundant configuration). For active line security systemsAES128 bit encryption shallbe enabled (at the monitoring station receiver)
and the supervision heartbeat rate shallbe set as90 seconds(panel section [851][004] = 005A/90). The supervision window at the SignalReceiver Center
(SRC)'sreceiver shallbe programmed asmaximumof 180 (00B4/180) seconds.
NOTE: For ULC commercialfire passive communication, encryption shallbe enabled,
•For UL Residential Fire and Burglary applications the TL2803G(R)E/3G2080R/TL280(R)E/LE2080(R) /TL280LE(R) can be used asthe primary com-
munication channelvia either cellular or Ethernet, or asa back-up in conjunction with the DACT (30 daytest transmission isrequired on each channel).
Level
SPT according to SP4 and DP3
SPT according to SSPT according to SP4 and DP3P4 and DP3
SPT according to SP4 and DP3 (depending on cellular carrier used)
SPT according to SP4 and DP3 (use AES- 128 and authentication/sequential
information in each message transmitted to the SG receiver)
SPT according to SP4 and DP3 (use AES-128 encryption)
Use single communication path for models 3G2080 (R) E- EU/LE2080- EU
(cellular network), TL280(R) E(Ethernet port) (SPT according to SP4) and two
communication paths for model TL2803G (R) E- EU/TL280LE- EU
(cell/Ethernet). (SPT according to SP4 or DP3)
ATSfailure reported to ARC, SPT according to SP4 and DP3
ATS failure
HS2128/HS2064/HS2032/HS2016). SPT according to SP4 and DP3
There isno recording of availabilityfailure
No logging function provided
No memoryprovided for logging function
ATSfailure reported to ARC
Maximum Power
Class4 (2W) @ 900MHz, GSM
Class1(1W) @ 1800MHz, GSM
ClassE2 (0.5W) @ 900MHz, EDGE
ClassE2 (0.4W) @ 1800MHz, EDGE
Class3@700(FDD28)/800(FDD20)/900 (FDD8)/1800(FDD3)/2100(FDD1)/2600(FDD7) MHz