NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test trans-
mission.

Cellular Receiver 1 Options

[200] Cellular Receiver 1 Options
Option 1: Cellular Receiver 1 Enabled - Default ON/OFF
ON: Cellular receiver 1 is enabled.
OFF: Cellular receiver 1 is disabled.
Option 2: Cellular Receiver 1 Supervision Enabled - Default OFF
ON: Cellular receiver 1 is supervised and heartbeats are sent to cellular receiver 1 based on the supervision interval pro-
grammed in section [207].
OFF: Cullular receiver 1 is not supervised.
[201] Cellular Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel
account number. Valid range: 0000000001 - FFFFFFFFFE. Programming all 0's or all F's will cause a module configuration
trouble (yellow LED = 12 flashes).
[202] Cellular Receiver 1 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central station. Valid range:
000000 - 099999. Values are entered as a leading 0 followed by the 5-digit DNIS.
[203] Cellular Receiver 1 Address
Default (000.000.000.000)
Enter the cellular receiver 1 IP address. This information will be provided by the central station system administrator. Each
3-digit segment of the address must be within a valid range of 000-255.
NOTE: When a valid IP address has been entered, the cellular receiver is enabled and will communicate events over the
cellular channel.
[204] Cellular Receiver 1 Port
Default (0BF5/3061)
This section determines the port used by cellular receiver 1. Change the default value of this port when the installation is loc-
ated behind a firewall and must be assigned a particular port number as determined by the central station system admin-
istrator. Valid range: 0000 - FFFF.
NOTE: Programming this section with 0000 will disable the receiver.
[205] Cellular Receiver 1 APN
Default ()
The Access Point Name (APN) determines the cellular network that the communicator will connect to. This information is
available from the network carrier. Program this section as 32 ASCII characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet. DLS and remote flash can
still be done if section [221] is programmed with a valid public APN.
[206] Cellular Receiver 1 Domain Name
Default ( )
Enter the Domain Name as 32 ASCII characters. This information will be provided by the central station system admin-
istrator.
[207] Cellular Receiver 1 Supervision Interval
Default (0087/135 seconds)
The supervision interval is only valid if supervision has been enabled for Cellular receiver 1 in section [200] . The receiver
supervision interval determines the delay, in seconds, between each heartbeat signal sent to the central station receiver. If
the interval programmed is less than 10 seconds (000A), supervision is disabled. The valid range for this section is 000A –
FFFF seconds.
NOTE: The supervision interval programmed inthe central station receive must be 65s longer than the interval pro-
grammed in the communicator to ensure stable operation.

Cellular Receiver 2 Options

[210] Cellular Receiver 2 Options
Option 1: Cellular Receiver 2 Enabled - Default ON/OFF