HS2016/2032/2064/2128
AC AC
AUX+
Item
Description
1
To External Antenna
AUDIO / DEFAULT
2
Jumper pins 4 and 5 to reset
3
Network Link - Yellow
From NID use only CAT5 supervised
4
maximum cable length 100m (328 feet)
5
RS-232 to third party device
6
RED Wire
* Wire colors based on the cable provided in the product box.
6.
Perform the following steps for initial power on of the panel with communicator installed:
a.
Reconnect the AC power, telephone line, and battery + connector to the panel.
(The communicator and panel will power up together).
b.
The communicator's red and yellow LEDs flash together while it initializes. The red and yellow LEDs will continue
to flash until the communicator has successfully communicated to all programmed receivers.
NOTE: During radio reset, the two green LEDs will flash alternately.
Figure 3: Communicator Wiring Diagram
PCLINK_2
UA621
5
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM
PGM2
PGM4
Table 8: RS-232 Connections
3rd Party Device
TX (RED)*
Unused
RX (GRN)*
Unused
GND (BLK)*
1
L
SIM
o
c
3G/LTE Radio
k
TL2803G(R)E
DSC
3G2080(R)E
UA685
TL280(R)E
TL280LE(R)
6
LE2080(R)
PC-LINK
Z6 Z7 COM Z8
RING
TIP
T-1
R-1
Input Ratings:
+10.8V ~ +12.5VDC
l
90mA 3G2080(R)E/120mA TL2803G(R)E standby
l
90mA 3G2080(R)E/ LE2080(R)/LE2080-EU
l
120mA TL2803G(R)E/TL280LE(R)/TL280LE-EU
l
100mA TL280(R)E
l
400mA alarm
l
DSC Panel minimum power requirements:
16.5 VAC 40 VA transformer
l
12 VDC 7Ah battery
l
Communicator
RX+
RX-
TX+
TX-
GND
15