Valid entries are 01 - 05:
01 = 9600 Baud
02 = 19200 Baud
03 = 38400 Baud
04 = 57600 Baud
05 = 115200 Baud
[421] Serial Port Settings (for use with 'R' models only)
[1] Parity Enabled Default (OFF)
ON: Parity
OFF: No Parity
[2] Parity Type Default (OFF)
ON: Odd Parity
OFF: Even Parity
[3] Stop Bits Default (OFF)
ON: Two Stop Bits
OFF: One Stop Bits
[4] Flow Control Default (OFF)
ON: Flow Control
OFF: No Flow Control
[5] - [8] Reserved
[422] Integration Identification Number
This section will display the unique 12- digit number assigned to this communicator for the identification when integrated
with third party applications.
[423]Session 1 Integration Access Code
Default (12345678) Valid Range is 00000000 - FFFFFFFF
This section is a programmable 8-digit number used for initialization with third party applications.
[424] Session 1 SMS Label
Default (11111111)
Program this section with a label that is used to validate a connection between the communicator and third party software
over cellular.
[425] Session 1 Integration Toggle Options 2
The toggle options in this section are used to enable and configure the path used for integration with third party applic-
ations.
[1] Integration Over Serial Port Default (ON)
[2] Integration Over Cellular Default (OFF)
[3] Integration Over Ethernet Default (OFF)
Note: Only one serial or cellular integration session can be configured for use with the product. Cellular integration is only
available outside of the USA/Canada.
TL280LE / TL2803G v5.5 Dual Path Ethernet/Cellular communicators allow one integration session to use the Ethernet
channel as the primary connection to a remote integration server, and if Ethernet fails due to an ISP trouble, connect to the
integration solution using cellular instead. To enable the Integration Backup feature on dual-path communicators, enable
option [3] Integration over Ethernet and [2] Integration over Cellular in section [425], and ensure Option [4] is disabled in sec-
tion [005] so Ethernet is the primary technology used for communications.
The communicator will automatically reconnect to the server using Ethernet when the path restores.
Integration Backup is supported when no polling, UDP polling, or TCP polling applications are used.
Before using this feature, confirm with the integration partner if it is allowed, and that an adequate data plan is active on the
SIM card.
[4] Type 2 Encryption Default (OFF)
[5] Integration Protocol Default (ON)
[6] Interactive Protocol SMA Default (OFF)
[7] Reserved
[8] Interactive Encryption for SMA Default (ON)
[426] Session 1 Integration Toggle Options 3
The toggle options in this section are used to determine the polling and notification behavior used for integration with third
party applications.
[1] UDP Polling Default (OFF)
[2] TCP Polling Default (OFF)
[3] Real-time Notification Default (OFF)
37