Glass Gasket; Glass Replacement; Valve Assembly Replacement - Regency Classic C34 Series Owners & Installation Manual

Direct vent freestanding gas stove
Table of Contents

Advertisement

GLASS GASKET

If the front glass requires replacement use (Part
# 846-302).
GLASS
REPLACEMENT
Your CLASSIC stove is supplied with high tem-
perature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. In the event that you break your glass by
impact, purchase your replacement glass from an
authorized Regency
®
dealer only.
REMOVING VALVE
ASSEMBLY
1. Shut off gas and electrical supply.
2. If optional fan is installed, disconnect power
source to stove.
3. Remove access panel.
a ) Fr o n t p a n e l o n p e d e s t a l m o d e l .
See Diagram 1.
b) Panel from bottom of leg shield.
See Diagram 2.
Note: Access panel only has to be loosened
to be taken out.
4. Remove valve cover plate by removing two (2)
screws.
5. Disconnect receiver wire.
6. Remove cover plate by removing 4 screws
(Pedestal option only).
Cover Plate
Access Panel
Diagram 1
Diagram 2
7. Disconnect gas line to stove.
8. Disconnect 3/8" NPT pipe from 90
valve.
9. Disconnect the two (2) switch wires from valve.
10. Disconnect three (3) fan wire from DC sparker.
11. Remove orifice.
12. Loosen four (4) Phillips head M5 valve mounting
screws from underside of firebox. Drop valve
assembly down.
Regency
maintenance
To remove valve from valve assembly,
continue.
Valve Cover
13. Remove two (2) thermopile wires.
Plate
14. Remove thermocouple with a 9 mm (metric)
wrench.
15. Remove pilot nut with an 11 mm wrench.
16. Remove valve to orifice nut with a 13/16"
wrench.
17. Remove inlet pipe with pipe wrench. Note
orientation of 90o elbow.
18. Remove two (2) phillips head M5 screws on
each side of the valve.
19. Remove valve and remove gas out 90o brass
fitting. Note orientation of fitting.
See Diagram in "Optional Fan Installation"
section for more detail.
INSTALLING
VALVE ASSEMBLY
1. To install a new valve assembly, reverse
instructions for removing valve. See as-
sembly steps 1-10.
2. Check for leaks and manifold pressure. See
Gas Pressure Test instructions.
3. To reinstall valve, reverse instructions for
o
elbow on
removing valve assembly, steps 11-17.
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
®
|