RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations
Alternate
Horizontal
Termination
Caps
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
Riser is acceptable with all systems.
This product has been evaluated by Intertek for
use with Duravent Direct-Vent , Selkirk Direct-
Temp, Ameri Vent Direct venting and Security
Secure Vent systems.
The FPI AstroCap
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
can Metal Products Ameri Vent Direct Vent, Security Secure Vent
International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
18 |
Regency
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
®
Vertical
Termination
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
and FPI
TM
, Selkirk Direct-Temp. AstroCap
®
Cap
Adj.Pipe Length
o
90 Elbow
24" Pipe
Length
is a proprietary trademark of FPI Fireplace Products
TM
Vinyl Siding
Standoff (Optional)
Wall Thimble
11" - 14-5/8"
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to unit.
Direct Vent, Ameri-
®
Horizontal
Termination Cap
# 946-523/P