MAINTENANCE

MAINTENANCE
INSTRUCTIONS
Any maintenance required accessing the
glass door of the unit must be performed
by an authorized service person.
1) Always unplug the power cord before
cleaning. For relighting, refer to lighting
instructions. Keep the burner and control
compartment clean by brushing and vacu-
uming at least once a year. When cleaning
the logs, use a soft clean brush as the logs
are fragile and easily damaged.
2) Clean glass (never when unit is hot), appli-
ance, louvres, and door with a damp cloth.
Never use an abrasive cleaner. The gold
louvres (and optional gold door) may be
scratched if abrasives are used to clean
them.
The heater is finished in a heat resistant
paint and should only be refinished with
heat resistant paint (not with wall paint).
Regency uses StoveBright Paint - Metallic
Black #6309.
3) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making sure
the flames are steady; not lifting or floating.
If there is a problem, call an authorized
service person.
4) The appliance and flueing system must be
inspected before use, and at least annu-
ally, by an authorized field service person,
to ensure that the flow of combustion and
ventilation air is not obstructed.
During the annual service call, the burners
should be removed from the burner tray
and cleaned. Replace the embers - do not
block the burner ports.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
WA R N I N G : C H I L D R E N A N D
ADULTS SHOULD BE ALERTED
TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID
BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
Regency FG38 FireGenie Freestanding Gas Stove
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR
SERVICING AN APPLIANCE MUST
BE REPLACED PRIOR TO
OPERATING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT
BE PLACED ON OR NEAR THE
APPLIANCE.
DO NOT USE THIS APPLIANCE
IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL AN
AUTHORIZED SERVICE TECHNI
CIAN TO INSPECT THE APPLI-
ANCE AND TO REPLACE ANY
PART OF CONTROL SYSTEM AND
ANY GAS CONTROL WHICH HAS
BEEN UNDER WATER.
6) Verify proper operation after servicing.

LOG REPLACEMENT

The unit should never be used with broken logs.
Unplug the power cord and allow the unit to
cool before opening door to carefully remove
the logs. If for any reason a log should need
replacement, you must use the proper replace-
ment log. The position of these logs must be as
shown in the diagram under Log Installation.
Note:
Improper positioning of logs may
create carbon build-up and will alter
the unit's performance which is not
covered under warranty.
DOOR AND GLASS
GASKET
If the door gasket requires replacement use
7/8" diameter oval door gasket (Part # 650-920).
The glass requires 5/8" flat glass gasket. See
your Regency dealer.
GLASS
REPLACEMENT
Your Regency heater is supplied with high tem-
perature, 5mm Neoceram silica coated ceramic
glass that will withstand the highest heat that
your unit will produce. In the event that you break
your glass, purchase your replacement from
an authorized Regency dealer only, and follow
the step-by-step instructions for replacement.
Removing Glass:
Note: Wearing gloves will protect your
hands while handling glass.
1) Remove the door from the unit and place
on a soft surface to prevent scratching.
2) Pull out the door gasket.
3) Remove the 24 nuts holding the glass
retainers in place. Do not remove the nuts
underneath the retainers.
4) Remove the door catch plate.
5) Remove glass retainers on sides first (3 each
side) then remove two center retainers.
6) Remove glass from door assembly. When
removing glass, leave white insulation in
place.
7) Reverse steps 6 - 2.
Safety Screen: Only required in Australia